Deleting Sensors
23
Deleting
Sensors
You can delete a single sensor or all sensors at once.
¾
To delete a single sensor:
1. Open the front cover.
2. Enter the Utility 1 or Utility 2 Access Code.
3. Press the Delete button. The panel announces “Select from Main Menu.”
4. Press Sensor from the Main Menu. The panel says “Sensor X panic. Press Sensor again for
next sensor or done to delete.”
Note
If no sensors have been learned into the panel the panel says “Function not available” after the sensor
button is pressed.
5. Press the Sensor button until the panel announces the number of the sensor you wish to
delete.
6. Press the Done button to delete the sensor.
¾
To delete all sensors:
1. With the front cover closed, press the Menu button on the back of the panel until the panel
announces “Delete all sensors. Press status to delete all sensors.”
Note
Pressing the Menu button cycles through 5 functions; Phone Test, Sensor Test, Medication Reminder,
Add Sensor and Delete all Sensors. The panel will announce the current function each time the button
is pressed.
2. Press the Status button on the front of the panel to delete all sensors. The panel says “All sen-
sors deleted.”
System
Monitoring
The CareGard system constantly monitors system conditions to ensure proper operation.
AC Power
¾ The panel Power light either blinks or remains lit if AC power is connected. If AC power
is not detected for 6 seconds or more, the following occurs:
1. The panel Power light turns off.
2. After 4 minutes, a non-reporting AC fail report will be placed in the event buffer.
Note
If Status is pressed during
an AC power failure the sys-
tem will announce “AC
power failure” and the sys-
tem will stop beeping for 4
hours.
3. If Option 25: Trouble Beeps is enabled, six trouble beeps will sound once a minute.
4. After the AC Power Failure Report time (Option 17) expires, the panel reports an AC power
failure message to the central station.
¾
When AC Power is restored for more than 2 seconds:
1. The panel sends a AC power restoral message to the central station if an AC failure message
was sent. If an AC failure message was not sent, the panel places the AC restoral message in
the event buffer as a non-reporting event.
2. The Power light turns on (or blinks).
3. Trouble beeps stop.
4. If the power has been removed for a while the panel may indicate it has a low battery. The
message will stop when the battery is recharged.
Backup Battery
¾ If the rechargeable backup battery reaches the low battery threshold during a battery
test or if operating on battery backup during an AC failure, the following occurs:
1. The panel sends a CPU low battery report to the central station if Option 18: CPU Low Bat-
tery is enabled.
Note
If Status is pressed during a
CPU low battery, the system
will announce “Time is x:xx,
system low battery” and the
panel will stop beeping for 4
hours.
2. If Option 25: Trouble Beeps is enabled, six trouble beeps will sound once a minute.
When the battery is charged or replaced and a sensor test is performed, the system sends a CPU
low battery restoral report to the central station if Option 18: CPU Low Battery is on.