Programming Options
11
Option 11: Phone Mod 2
Range = 00-10 (Default = 00)
Determines what (content) and how (format) the panel should report through
the secondary phone number (Option 4), if one is programmed. Table 3
describes the choices. All Entries must be 2 digits.
¾
To program Phone Mod 2:
1. Press Add.
2. Press Option #.
3. Press 1, then 1 again.
4. Enter a Phone Mod 2 using the numbered
buttons.
5. Press Done.
Table 3: Phone Mod 2 Settings
Setting Content Format
00 All SIA
01 All Contact ID
02 Alarms Only SIA
03 Alarms Only Contact ID
04 Non-Alarms Only SIA
05 Non-Alarms Only Contact ID
06 Phone 1 Failure SIA
07 Phone 1 Failure Contact ID
08 AC Power Restorals/Failures, Medication Reminder,
Activity Timer and Phone Test
Pager
09 Same as 08 plus Alarms Pager
10 Alarms only (See Options 5 and 12) Voice Event
Notification
Option 12: Numeric Pager/Voice Event Notification Phone
Mod 3
Range = 08-10 (Default = 10)
Determines what (content) and how (format) the panel should report through
a Numeric Pager/Voice Event Notification Phone Number (Option 5), if one
is programmed. Table 4 describes the choices. All entries must be 2 digits.
¾
To program Phone Mod 3:
1. Press Add.
2. Press Option #.
3. Press 1, then 2.
4. Enter a Phone Mod 3 setting using the num-
bered buttons.
5. Press Done.
Table 4: Phone Mod 3 Settings
Setting Content Format
08 AC Power Restorals/Failures, Medication Reminder,
Activity Timer and Phone Test
Numeric
pager
09 Same 08 plus Alarms Numeric
Pager
10 Alarms Only Voice Event
Notification