– 34 –
Overfl ow Water Level
Operation of the water level control can be checked
by using service test mode t06. (See
Service Test
Mode.)
Specifi c failures associated with the water level
control can initiate error codes E23 and E62. (See
Service Test Mode.)
The overfl ow water level is approximately 6
1
/
2
inches
above the door opening. Over ow protection will
occur at this water level.
(Continued Next Page)
Pressure Tube
Tabs
To remove the water level control:
Remove the top panel. (See Top Panel.)
Press down the single tab, then disconnect each
of the 2 wire harnesses.
Remove the pressure tube.
Note: The pressure tube is diffi cult to remove.
a. Squeeze the clamp and slide it back.
b. Carefully break the hose loose by inserting a
small fl at-blade screwdriver under the hose
to break the seal.
c. Remove the hose.
Pull the bottom of the water level control outward,
rotate it
1
/
4
-turn clockwise to clear the suspension
spring.
1.
2.
3.
Water Valve
The water valve assembly consists of a valve body
and two solenoid coils. The water valve has a fl ow
rate of 2.1 gallons (8 liters) per minute. It is inserted
and retained in a cutout in the rear of the cabinet
and held in place by a single 6-mm hex-head screw.
It is only available as a complete assembly.
Each solenoid coil has an approximate resistance
value of 1.1K Ω.
Operation of the water valve can be checked by
using service test modes t08 and t09. (See Service
Test Mode.)
Specifi c failures associated with the water valve can
initiate error codes E22 and E62. (See Service Test
Mode.)