GEH-5820C
Powr•Spot
®
Floodlight
INSTRUCTIONS
GENERAL
This luminaire is designed for outdoor lighting service, and should not be used in
areas of limited ventilation, or in high ambient temperature enclosures. Best results will
be obtained if installed and maintained according to the following recommendations.
UNPACKING
The system consists of three components; ballast, optical reector (with and
without a heavy-duty optical cover) and glass lens. If luminaire is ordered with a
PSFA (See Figure 1A) prex glass lens is shipped in same carton as optical reector.
With a ULGC (See Figure 1B), PSGN (See Figure 1C), or PSGV (See Figure 1D), glass
lens will be in a third carton with glare control device in place. Component catalog
numbers for each of assemblies are shown in Table 1. Included in table are NEMA
beam descriptions for each reector catalog number. This is VERY IMPORTANT when
more than one light distribution is to be used.
Bill of lading lists component catalog numbers in addition to complete system
catalog number. Component catalog number is a prominent feature of label on
carton and is conspicuously displayed on outside of each component. Each optical
reector has label displaying a reector "ID" which consists of fth (5) and eighth (8)
alpha/numeric character from its component catalog number: xxxx"A"xx"N". This
can be seen from ground.
Check to see that you have received the correct material undamaged in transit.
INSTALLATION
WARNING
Risk of electric shock
• Turn power o before servicing
– see instructions
CAUTION
Unit will fall if not installed properly
• Follow installation instructions
FIGURE 3
PSFA
FIGURE 1A
PSGV
All 20" Reector ID's
FIGURE 1D
ULGC/ULGN/ULGV
All 20" Reector ID's
FIGURE 1B
PSGN
All 20" Reector ID's
FIGURE 1C
READ THOROUGHLY BEFORE INSTALLING
A. CROSSARM SPACING:
These dimensions should preclude physical interference between oodlights
– when visors or other external accessories are used the vertical spacing will be
greater – contact factory.
HORIZONTAL spacing between oodlights 30"
VERTICAL spacing 36" without Top Visor
VERTICAL spacing 52" with Top Visor
B. MOUNTING:
Floodlight is provided with either a straight or angled trunnion bracket for
mounting on at surfaces. Trunnion brackets have a clearance hole for a 3/4-
inch
bolt (Tighten to 80-90 Ft. Lbs.). Angled trunnion has a slot for a 3/8-inch
bolt for anti-rotate feature. Hole pattern required for 180 degrees of rotational
freedom of angled trunnion is shown in gure 3. Note that clearance hole for
3/4-inch bolt needs to be at least 1.125-inches from edge of at mounting surface
(See gure 3).
Special mounting adapters are available for other applications.
CAUTION: Drain holes are provided for normal below-horizontal aiming. Drain
hole knockouts are provided for above-horizontal aiming. Two drain hole
knockouts are on back of casting and one is on back of socket housing. (See
Figure 2) Open these three holes if the unit is to be aimed above horizontal. It
is not necessary to close normal holes hidden below cover.
C. WIRING:
Make all electrical connections in accordance with the National Electrical Code
and any applicable local code requirements.
Verify that supply voltage is correct by comparing it to nameplate.
1. Remove cover (four screws).
NOTE: Cable strain relief and seal are provided by the casting V-notch, the rubber
bushing, and the cover.
9/16-inch O.D. three-conductor AWG #14 cable is recommended.
2. Insert cable through the rubber bushing and make electrical connections.
Optical Assembly MH MH MH HPS HPS HPS
Cat. No. REFL. 1500 1000 400 1000 750 400 REFL.
XX= GP or HD DIA. NEMA NEMA NEMA NEMA NEMA NEMA ”ID’’
PSFBBxx0 20" 3X3 3X3 3X3 — 3X3 3X3 B0
PSFBCxx0 20" 4X4 4X4 3X3 — 4X4 4X4 C0
PSFBDxx0 20" 5X5 5X5 5X5 — 5X5 5X5 D0
PSFBExx0 20" 6X6 6X6 6X6 5X5 5X5 6X6 E0
PSFBAxx2 22" 2X2 2X2 1X1 — — 1X1 A2
PSFBBxx2 22" 3X3 3X3 2X2 — — 2X2 B2
ULGCBxx0 20" 3X3 3X3 — — — — B0
ULGCCxx0 20" 4X4 4X4 — — — — C0
ULGCDxx0 20" 5X5 5X5 — — — — D0
ULGCExx0 20" 6X6 6X6 — — — — E0
*PSGNBxx0 20" 3X3 3X3 — — — — B0
*PSGNCxx0 20" 4X4 4X4 — — — — C0
*PSGNDxx0 20" 5X5 5X5 — — — — D0
*PSGNExx0 20" 6X6 6X6 — — — — E0
* Glare control optics may dier from base reector
NEMA Beam spreads.
Base Reector Catalog Numbers and NEMA Beam Spreads*
TABLE 1
TOP LENS GLASS CLIP
REFLECTOR
REPOSITIONING STOP
TRUNNION BRACKET
DRAIN HOLE
KNOCK-OUTS
COVER
GP
REFLECTOR
WITH LENS
VISOR WITH
GLARE SHIELD & LENS
DRAIN HOLE
KNOCK-OUT
BALLAST
g
GE
Lighting Solutions
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance.
Should further information be desired or should particular problems arise which are not covered suciently for the purchaser’s purposes, the matter should be referred to GE Lighting Solutions.
FIGURE 2