GE ABV1 Installation Guide Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
ALB015-043014
Troubleshooting
Symptom Solution
Luminaire will not turn on. • Check that the color of the supply side wires match the color of the wires they are connected to.
• Check that all wire connectors are properly connected.
• Verify that your input voltage is within specs.
• If you are using any additional controls (i.e. wireless controls/motion sensors), please also verify that
those are working properly and that the unit is setup to interface with the controllers.
Mounting insert slides
from side to side.
• Check that the mounting insert is properly tightened using the adjustment screws provided.
1
3
2
4
Attach pendant mount bracket hub to 3/4“ conduit
and pass AC input wires through conduit and mounting
bracket. Determine rotation of xture and lock
orientation in place with provided set screw.
Connect AC input wires to xture wires and reattach
power access plate.
Lift xture up until the pendant mount bracket snaps
into mounting features. Let the xture hang and
determine if the bracket needs to be moved for balance.
Attach (2) 8-32 x 3/8” screws to pendant mount bracket
to lock position. Do not over tighten screws.
Fasten (2) endplates to bracket with 8-32 x 3/8” screws.
Pendant Mount Kit
OPTION B
GE Lighting • 1-888-MY-GE-LED (1-888-69-43-533) • www.gelighting.com
The GE brand, logo, and Albeo are trademarks of the General Electric Company. © 2014 GE Lighting.
Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
Attach to
structural member
Page view 3