ALB015-043014
Troubleshooting
Symptom Solution
Luminaire will not turn on. • Check that the color of the supply side wires match the color of the wires they are connected to.
• Check that all wire connectors are properly connected.
• Verify that your input voltage is within specs.
• If you are using any additional controls (i.e. wireless controls/motion sensors), please also verify that
those are working properly and that the unit is setup to interface with the controllers.
Mounting insert slides
from side to side.
• Check that the mounting insert is properly tightened using the adjustment screws provided.
1
3
2
4
Attach pendant mount bracket hub to 3/4“ conduit
and pass AC input wires through conduit and mounting
bracket. Determine rotation of xture and lock
orientation in place with provided set screw.
Connect AC input wires to xture wires and reattach
power access plate.
Lift xture up until the pendant mount bracket snaps
into mounting features. Let the xture hang and
determine if the bracket needs to be moved for balance.
Attach (2) 8-32 x 3/8” screws to pendant mount bracket
to lock position. Do not over tighten screws.
Fasten (2) endplates to bracket with 8-32 x 3/8” screws.