NX-8V2 Control 47
Dual / Split / Multiple Reports
The NX-8V2 can send communication reports to three different phone numbers for dual, split or multiple reports selectable by event or
partition. (Loc 4, 10, & 16, pg 12, 13, 14)
Duress Code
If a duress code is programmed the NX-8V2 will send a duress signal whenever the panel is armed or disarmed with this code. If
open/close reports are sent, the user code will be 254. (Loc 44, pg 21)
Dynamic Battery Test
The NX-8V2 can be programmed to perform a Dynamic Battery Test for a selected duration the first time the panel is armed or
disarmed every day, as well as by using
r4 (Test function). If the panel is not armed or disarmed during the day, it will perform the
test at midnight. The NX-8V2 can also be programmed to perform a missing battery test every 12 seconds. (Loc 37 & 40, pg 19 & 20)
Early to Open / Late to Close
If an opening occurs before the opening and closing times, the NX-8V2 will send an “Early Open” report. If it fails to close on or before
the designated closing time, the NX-8V2 will send a “Late to Close” report.
End of Line Resistor Defeat
NOTE: For UL installations, all zones must be programmed as supervised.
The NX-8V2 can be programmed to make zones 1-8 for normally closed operation only, eliminating the need for the end of line resistors
on these zones. When a zone is programmed for normally closed operation, a short on that zone will not change the loop condition, and
an open on that zone will produce a faulted condition. This feature will be ignored by any Priority zone. (Loc 111-169, pg 28-31)
Entry-Guard
NOTE: For UL installations, this feature shall be disabled.
This unique low level arming mode has been developed to reduce the most common source of false alarms. When armed with the
AInstant@ LED on, the opening of any zones designated as "Entry Guard zone" will initiate the keypad sounder and start the entry delay
before creating an alarm. All other zones will function as normal. This arming mode will encourage system owners to use their system
more frequently when the premises are occupied. (Loc 111-169, pg 28-31)
Exit Error
If enabled, the NX-8V2 will send an "Exit Error Report" if an entry/exit zone is faulted at the instant the exit delay expires. This report
will be sent along with the user number that armed the system, if the panel is not disarmed before the entry delay expires. The alarm
report will also be sent. Even if this feature is not enabled, the siren will sound if any entry/exit zone is faulted at the instant the exit
delay expires. (Loc 23, pg 15)
Expander Trouble
The NX-8V2 will report expander trouble to the central station if enabled. This condition will illuminate the "Service" LED on the keypad
even if not reported. NOTE: The keypads are considered expanders. The expansion device number that will report can be found on
page 52. (Loc 37, pg 19)
Fail to Communicate
The NX-8V2 will illuminate the "Service" LED if a report fails to reach the central station. If enabled, when the next report is successfully
communicated, a Fail to Communicate code will be reported. (Loc 37, pg 19)
Fire Alarm Verification
When enabled, the NX-8V2 will verify a Fire alarm by requiring more than one trip on a smoke detector within a specified time before
creating an alarm. (Loc 40, pg 20) This feature is not approved for residential use in California.
First to Open / Last to Close
The first partition that opens from a completely armed system (all valid partitions armed) will send an “Open” report. All other partitions
opened will be log only. The last partition to close from a completely armed system (all valid partitions armed) will report to the central
station. Any prior closing(s) will be log only. (Loc 37, pg 19)
Force Arming
NOTE: For UL installations, this feature shall be disabled.
When enabled, the NX-8V2 can be Force Armed with zones violated. Under this condition, if a force armable zone is not secure, the
"Ready" LED will flash. At the end of the exit delay, these zones will become bypassed. If these zones become secured any time during
the arming cycle, they will be unbypassed and active in the system. If "Bypass Report" is enabled, the force arming zones can be
programmed to report bypass when they are Force Armed (default), or to not report bypass even if "Bypass Report" is enabled. (Loc
37 & 111-169, pg 19 & 28-31)
Ground Fault
A fault of the earth ground can be reported to the central station. Even if it is not reported, this condition will illuminate the "Service" LED
on the keypad. (Loc 37, pg 19)
Group Bypass
NOTE: For UL installations, this feature shall be disabled.
A designated group of zones can be programmed to bypass by pressing [Bypass]- [0]-[Bypass]- [Bypass] prior to arming. (Loc 111-
169, pg 28-31)
Immediate Restore By Zone
The NX-8V2 can be programmed to send alarm and restore reports as soon as they occur, or wait until the siren time has expired. (Loc
37, pg 19)
Internal Event Log
Up to 512 events can be stored in memory along with the date and time of the event. These events can later be viewed through
downloading. All reportable events report to the log.
Keypad Activated Panics
The NX-8V2 has three keypad activated panics that will send reports to the central station: Auxiliary 1 (Fire), Auxiliary 2 (Medical), and
Keypad Panic. Auxiliary 1 will activate the steady (Fire) siren, Auxiliary 2 will sound the keypad, and the Keypad Panic can be
programmed to be silent or audible (sound siren). (Loc 23, pg 15)
Keypad Sounder Control
The NX-8V2 can be programmed to sound the keypad sounder for certain events. (Loc 39, pg 20)
Keypad Tamper
If enabled, the NX-8V2 will disable the keypad for 60 seconds and communicate a tamper signal to the central station if 30 keypresses
are entered without producing a valid code. (Loc 23, pg 15)