GE mn-36005_series Service Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
© 2014 General Electric Company. All rights reserved.
6 | GE Oil & Gas
removal of the bracket is not required.
Before proceeding determine valve action (air
to open/air to close)
G. Slide lever (32) back onto shaft in desired position.
Slide indicator arm (35) back onto shaft. Align bracket
and slide back onto mounting studs (26) and packing
flange studs (25). Replace mounting stud nuts (24)
and washers (18). Slide packing flange (23) back onto
packing flange studs (25) and replace packing flange
stud nuts (24).
H. Remount actuator onto housing and replace actuator
mounting hex nuts (75) and washers (76). Position lever
(32) so that rod end bearing (94) lines up in lever (32)
and that the pads on the lever will contact the stop
bolts (102). Tighten lever cap screw (33).
I. Rotate ball plug (2) to closed position. Adjust closed
position travel stop (102) until it contacts the pad on
lever (32). Tighten locknut (101).
J. Rotate ball plug (2) to open position. Adjust open
position travel stop until it contacts pad on lever (32).
Tighten locknut (101).
Ensure rotation of AC actuator does not
exceed 90deg� Damage to actuator rod may
result
K. If actuator action is air to open, rotate ball plug (2) to
open position. Pneumatically stroke actuator to open
position. Loosen rod end bearing locknut (93) and
adjust position of rod end bearing (94) so that holes in
lever (32) and rod end bearing (94) line up. Insert pivot
pin (39) and retaining rings (40).
When stroking valve keep hands and
equipment clear of ball plug and seal ring
to avoid injury or damage to personnel and
equipment
L. If action is air to close place ball plug (2) in closed
position. The pad on lever should contact the closed
position travel stop (102). If it does not, repeat
adjustment as noted in step I above. Return ball plug (2)
to open position. Pneumatically stroke actuator to open
position.
Do not exceed maximum air supply pressure�
Keep hands clear of actuator stem and linkage�
Loosen rod end bearing locknut (93) and adjust rod end
bearing (94) so that holes in lever (32) and rod end bearing
(94) line up. Insert pivot pin (39) and replace retaining rings
(40).
M. For both air to open and air to close action, stroke
valve fully to ensure proper closure of ball plug and
operation of valve. It may be necessary to readjust rod
end bearing slightly by loosening locknut and rotating
stem.
N. Replace handwheel assembly in housing (31), washer
(54-7) and retaining clip (54-4).
O. Replace shaft cover (42) and screw (43).
P. Set and lock indicator arm (35) to indicate plug position.
2�5 Changing Valve Action
Note: If the valve action is to be changed it should be
done before the valve is installed in the line. This allows
a positive visual check to ensure that the ball plug is
fully closed when the actuator is in the proper position.
2�5�1 Model 33, sizes B & C only� For size AC refer
to section 2�5�2
A. If the valve is equipped with a handwheel disengage
the handwheel and remove retaining clips (63), clevis
pin (66), and pivot pins (39). Remove cap screws (70),
washers (71) and handwheel bracket (62).
B. If necessary, scribe a witness mark on the lever
(32) in relation to the slot on the end of the shaft (5).
Note: Standard lever has arrows stamped into it for
alignment. For handwheel lever use slot for alignment.
C. Remove pivot pin retaining clips (40), pivot pin (39) and
spacer rings (69). Remove shaft cover (42) and screw
(43). Remove actuator hex nuts (75) and washers (76).
Remove actuator.
Note: Spacer rings apply only on handwheel option.
D. Loosen lever cap screw (33). Remove packing flange
stud nuts (24), bracket mounting stud nuts (24) and
washers (18). Loosen ball plug indicator arm (35).
E. Slide bracket (31) away from body until it clears bracket
and packing flange mounting studs. Remove lever (32),
lever arm (64) and indicator arm (35) from shaft.
Before proceeding determine valve action (air
to open/air to close), refer to the appropriate
CAUTION
CAUTION
WARNING
DANGER