1�0 Introduction
The following instructions are designed to assist
maintenance personnel in performing most of the
maintenance required on the 36005 V-Max* valve and if
followed carefully will reduce maintenance time.
GE Masoneilan has highly skilled Service Engineers
available for start-up, maintenance and repair of our
valves and component parts. In addition, regularly
scheduled training programs are conducted to train
customer service and instrumentation personnel in
the operation, maintenance and application of our
control valves and instruments. Arrangements for these
services can be made through your GE Masoneilan
Representative or District Office. When performing
maintenance use only Masoneilan replacement parts.
Parts are obtainable through your local GE Masoneilan
Representative or District Office. When ordering parts
always include MODEL and SERIAL NUMBER of the unit
being repaired.
Numbering System
2nd
6
5th
5
4th3rd2nd
1st
1st
3
0 Undefined
1 Valve closes on stem
extension (Air to Close,
Fail Open)
2 Valve opens on stem
extension (Air to Open,
Fail Closed
3 Valve closes on stem
extension (Air-to-Close,
Fail Open)
4 Valve opens on stem
extension (Air-to-Open,
Fail Closed)
7 Valve closes on stem
extension (Air-to-Close,
Fail Open)
8 Valve opens on stem
extension (Air-to-Open,
Fail Closed)
Actuator Mounting
(See guide on page 4)
Body Series
36
5
Design Series
1 MN-7 Seal Ring
2 316 SS Seal
Ring
3 Heavy Duty
Metal Seal Ring
Seal Type
Actuator Type
33 Spring Diaphragm. Air to
extend action only.
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 31 32

Comments to this Manuals

No comments