MOUNTING
3
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
HANDLING
2
• This luminaire has been properly packed so that
no parts should have been damaged during transit.
• Inspect to conrm.
• Damage may occur if luminaire is improperly
handled outside of pack.
• Do not impact or stack luminaire after removal
from packaging.
• Open wiring compartment cover located on the
mounting bracket. Make electrical connections and
close wiring compartment cover.
Note: Make all electrical connections in accordance
with the National Electrical Code and any applicable
local code requirements.
UNPACKING
1
• Open Wiring compartment cover located on the
mounting bracket. Make electrical connections and
close wiring compartment cover. Seal wall mounting
ange to the mounting surface with silicone, caulk,
or equivalent.
3. Trunnion Mounted Units: Mount directly on a
at surface. The Trunnion bracket has a clearance hole
for a 3/4-inch bolt used for attachment. Tighten side
trunnion bolts to 15-20 foot pounds.
• Connect xture supply leads inside of customer
supplied junction box.
Note: Make all electrical connections in accordance
with the National Electrical Code and any applicable
local code requirements.
FIGURE 1
Set Screws
Follow Installation Instructions
1. Pipe Mounted Units:
The sliptter can be mounted
on 1-7/8-inch O.D. through 2-3/8-inch O.D. or 2-7/8 O.D.
through 3-inch O.D. pipes. Set screws are used to clamp
the oodlight security to the pipe. Tighten set screws to
15 foot-pounds (20.3 N•m). Sliptter is designed to mount
on a vertical pipe pointed upward such that gravity acts
to hold oodlight in place while the set screws are
tightened. Do not mount unit up-side-down.
2. Wall Mounted Units: The wall mounting plate
is provided with four .438-inch clearance holes spaced
4.375(H) x 2.875(V) inches for mounting. Do no mount
the unit such that the hinge side of door is higher than
the latch side of door.
FIGURE 2
2.875 in.
4 Holes
.4387 in.
4.375 in.
AIMING
3
1. Downward Aiming: On any orientations where
the glass is facing downward, remove the two power
door drain hole screws.
IMPORTANT: make sure all four rear drain holes are in
place on downward orientations
FIGURE 3
Remove Drain Screw
for downward position
Drain Screw remain
for downward position