Ge Monogram ZVC36 User Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
10
Advance Planning
DUCT FITTINGS
This Hood Must Use an
8Round Duct. It Can
Transition to a
3-1/4x 12Duct.
Use this chart to compute
maximum permissible lengths
for duct runs to outdoors.
NOTE: Do not exceed maximum
permissible equivalent lengths!
Maximum duct length:
100 foot for range hoods.
Flexible ducting:
If flexible metal ducting is used,
all the equivalent feet values in
the table should be doubled.
The flexible metal duct should
be straight and smooth and
extended as much as possible.
DO NOT use flexible plastic
ducting.
NOTE: Any home ventilation
system, such as a ventilation hood,
may interrupt the proper flow of
combustion air and exhaust
required by fireplaces, gas
furnaces, gas water heaters and
other naturally vented systems.
To minimize the chance of
interruption of such naturally
vented systems, follow the
heating equipment manufacturer’s
guidelines and safety standards
such as those published by NFPA
and ASHRAE.
Total
Equivalent Quantity Equivalent
Duct Piece Dimensions Length* Used Length
Round, 1 ft.
straight (per foot
length)
3-1/4x 12 1 ft.
straight (per foot
length)
90° elbow
17 ft.
45° elbow
10 ft.
3-1⁄4x 12
90° elbow 43 ft.
3-1/4x 12
45° elbow 26 ft.
3-1/4x 12
90° flat elbow 102 ft.
8round to
3-1/4x 12transition 2 ft.
3-1/4x 12to 8
round transition 5 ft.
8round
to 3-1/4x 12
transition 90° elbow 6 ft.
3-1/4x 12to 8
round transition 90° elbow 13 ft.
Round
wall cap
with damper 32 ft.
3-1/4x 12wall cap
with damper 75 ft.
Round
roof cap 44 ft.
Total Duct Run
*Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are
based on actual tests conducted by GE Evaluation
Engineering and reflect requirements for good
venting performance with any ventilation hood.
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 67 68

Comments to this Manuals

No comments