GE JV694 User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
4
INSTALLATION INSTRUCTIONS
This hood can easily be installed by following these
basic steps:
• Mark and cut out the cabinet bottom.
• Secure the hood to the cabinet.
• Mount the cabinet on the wall.
• Connect the ductwork and the power cable.
TOOLS YOU WILL NEED
Flat blade and Phillips
screwdrivers
Pencil
Duct tape
Saw (saber or keyhole)
Electric Drill
Metal Snips
(in some applications)
Pliers
Tape measure
Wire stripper
Flashlight
Caulking
Level
PLAN THE INSTALLATION
Caution: Remove the house fuse or open the
circuit breaker before beginning the installation.
Your new hood will fit a standard 36wide flush bottom
or recessed bottom, framed or frameless kitchen cabinet
which has a minimum depth of 11 from the face to
the inside of the back wall.
The unit is ducted vertically. To change to horizontal
ducting see the instructions.
For safe operation, the mounted hood must be
a minimum of 24above the cooking surface.
For easiest installation, the range hood should be
installed in the cabinet before mounting the cabinet to
the wall.
NOTE: Remove the glass visor from the
unit before installing the hood in the cabinet
to protect the visor from damage.
DUCT EQUIVALENT NUMBER
PIECES LENGTH X USED = TOTAL
3
1
4 x 10 1 Ft. x ( ) = Ft.
Rect.,
straight
3
1
4 x 10 14 Ft. x ( ) = Ft.
Rect. 90°
elbow
3
1
4 x 10 8 Ft. x ( ) = Ft.
Rect. 45°
elbow
3
1
4 x 10 33 Ft. x ( ) = Ft.
Rect. 90°
flat elbow
3
1
4 x 10 24 Ft. x ( ) = Ft.
Rect. (18 ft. w/o
wall cap damper) x ( ) = Ft.
with
damper
Total ductwork = Ft.
WORKSHEET—CALCULATE TOTAL
EQUIVALENT DUCTWORK LENGTH
MAXIMUM DUCT LENGTH: For satisfactory air
movement, the total duct length of a 3
1
4
x 10 rectangular
duct should not exceed 65 equivalent feet.
Page view 3
1 2 3 4 5 6 7 8

Comments to this Manuals