GE CT9070SHSS Instruction Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
3
ELECTRICAL REQUIREMENTS (CONT.)
This appliance must be supplied with the proper voltage and frequency and connected to an individual,
properly grounded branch circuit, protected by a circuit breaker or fuse. See the rating plate located on the
oven frame to determine the rating of the product.
Use the chart below to determine the minimum recommended dedicated circuit protection:
DO NOT shorten the flexible conduit. The conduit strain relief clamp must be securely attached to the
junction box and the flexible conduit must be securely attached to the clamp. If the flexible conduit will not
fit within the clamp, do not install the oven until a clamp of the proper size is obtained.
The 3 power leads supplied with this appliance are suitable for connection to heavier gauge household
wiring. The insulation of these 3 leads is rated for temperatures much higher than the temperature rating of
the household wiring. The current-carrying capacity of the conductor is governed by the wire gauge and the
temperature rating of the insulation around the wire.
Recommended
KW Rating KW Rating Circuit Size
240V 208V (Dedicated)
.: .: $PS
4.9 KW–7.2 KW 4.2 KW–6.2 KW 30 Amp
7.3 KW–9.6 KW 6.3 KW–8.3 KW 40 Amp
9.7 KW–12.0 KW 8.4 KW–10.4 KW 50 Amp
Rating plate
is located on
left side trim
Connected
Appliance
Information
is located on
right side trim
4
MAKE ELECTRICAL CONNECTIONS
WARNING
:
Switch power off at the service panel and lock the service disconnecting
means to prevent power from being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
Place oven on table or platform even with the cutout opening. For a French Door oven, the platform must
support 220 lbs. (98.8 kg). Connect the flexible conduit to the electrical junction box as shown below*.
Position the conduit in such a manner that it will lie behind the unit in a natural loop when the oven is
installed. You will need to purchase an appropriate strain relief clamp to complete the connection of the
conduit to the junction box.
* Ovens come equipped with a 40” long conduit. If a longer conduit is desired, there may be one available for
your model. To check availability or order parts, call 1.800.GE.CARES.
Junction Box
Conduit
Bare
Ground
Red
White
Black
Strain Relief Clamp
(not included) Must Be
Used at Junction Box
Place Oven on a
Support to Assist in
Connecting Conduit
Ground
Wire
Page view 3