Troubleshooting
Symptom Solution
Row of modules
does not light
• Check wire connections to power supply to ensure red stripe-to-red and white-to-black or blue connections.
• Check row-to-row polarity connections.
Sign does not light • Check input and output voltage and check power supply input/output connections.
• Check polarity connections.
Individual modules
do not light
• Remove module and replace with another working module.
Modules are dim • Ensure the overall length of the Tetra
®
LED system does not exceed the maximum load.
• Ensure the length and gauge of the supply wire is equal to or below the recommended remote mounting distance.
Specications
This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.
Conforms to the following standards:
GE Lighting Solutions • 1-888-MY-GE-LED (1-888-69-43-533) • www.gelighting.com
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting. The GE brand and logo are trademarks of the General Electric Company.
© 2014 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
Retrot Instructions
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the building. Ensure
that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have
a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or uorescent tubes; and associated transformers
and ballasts. Care should be taken not to break the existing neon or uorescent tubes.
NOTE: Follow all federal and local regulations when disposing of neon tubing, uorescent tubes, transformers and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, state, or country
electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in all
holes 0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13 mm), use an aluminum or
zinc coated steel patch with rivets and sealant.
5. Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
6. A Tetra
®
24VDC Class 2 Power Supply, as listed below, must be used with this retrot kit. Using the Maximum Loading chart below, determine the
number of Tetra
®
Class 2 Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload
the Tetra
®
Class 2 Power Supply chosen.
7. Follow the instructions above to properly mount the LED modules.
8. Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
9. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions found in the
power supply installation guide.
10. If required, the disconnect switch shall be installed by qualied personnel, in accordance with applicable local, state, and country electrical codes.
Maximum Remote Mounting Distance
18 AWG/0.82 mm
2
Supply Wire
16 AWG/1.31 mm
2
Supply Wire
14 AWG/2.08 mm
2
Supply Wire
12 AWG/3.31 mm
2
Supply Wire
20W Power Supply 120 ft./36.6m
80W Power Supply 20 ft./6.1m 25 ft./7.6m 35 ft./10.6m 40 ft./12.1m
100W Power Supply 20 ft./6.1m 25 ft./7.6m 35 ft./10.6m 40 ft./12.1m
180W Power Supply 20 ft./6.1m 25 ft./7.6m 35 ft./10.6m 40 ft./12.1m
Maximum Loading per Tetra
®
24 VDC Class 2 Power Supply
SKU Rating
20W Power Supply
Note: Load shall not
exceed 0.83A
80W Dimming
Power Supply
Note: Load shall not
exceed 3.3A
100W Power Supply
Note: Load shall not
exceed 4.0A
180W Power Supply
Note: Load shall not exceed 3.8A per
each (of 2) output channels
GEF12T12DHOLED,
GEF12T12CWHOLED,
GEF12T12SGNHOLED
24VDC
240mA/module
5.8W/module
3 modules/
4.4 ft. (1.33m)
12 modules/
17.4 ft. (5.30m)
16 modules/
23.2 ft. (7.07m)
14 modules/20.3 ft. (6.19m)
per output channel
28 modules/40.6 ft. (12.38m)
per power supply