Page view 1
Photometric Data: Lumination
TM
RS6
For more information and access to all of our resources, including our
design tool visit: www.gelighting.com
Installation:
Edison base installs into standard sockets
Universal mounting clips install into standard 6” downlight housings in minutes
Unique mounting clip design delivers a secure hold with easy removability
Construction:
16 gauge steel housing resists dents during transportation and installation
Spring steel mounting clips allow for several reinsertions without deformation
Optical System:
Flat lens for sleek, modern appearance
Edge-to-edge, uniform lit appearance with no hot spots or pixelation
Highly transmissive lens material for optimal combination of light transmission while diffusing
LEDs from direct view
Electrical System:
Integrated, high-efficiency driver with power factor > 0.9
Dimmable to 10% with most incansescent dimmers
• Instant-on
Product Specifications:
www.gelighting.com
GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property
of their respective owners. Information provided is subject to change without notice. All values are design or typical
values when measured under laboratory conditions. GE Lighting and GE Lighting Solutions, LLC are businesses of
the General Electric Company. © 2015 GE.
IND098 (Rev 01/28/15)
RS6 - 700 Lumen
COEFFICIENTS OF UTILIZATION
NOTE: Floor Cavity Reflectance : 20%
RC 80% 70% 50% 30% 10% 0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
1 111 107 104 101 108 105 102 99 101 98 96 97 95 93 93 92 90 88
2 103 96 90 85 100 94 89 84 90 86 82 87 84 81 84 81 79 77
3 95 86 79 73 92 84 78 73 81 76 71 79 74 70 76 72 69 67
4 88 77 69 64 85 76 69 63 73 67 62 71 66 61 69 65 61 59
5 81 70 62 56 79 69 61 56 67 60 55 65 59 54 63 58 54 52
6 75 63 55 50 74 62 55 49 61 54 49 59 53 49 58 52 48 46
7 70 58 50 44 69 57 50 44 56 49 44 54 48 44 53 47 43 41
8 66 53 45 40 64 53 45 40 51 44 40 50 44 39 49 43 39 37
9 61 49 41 36 60 48 41 36 47 41 36 46 40 36 45 40 36 34
10 58 45 38 33 57 45 38 33 44 37 33 43 37 33 42 37 33 31
Zone Lumens % of Fixture
0 - 30° 257 36.8
0 - 40° 406 58
0 - 60° 636 90.9
0 - 90° 700 100
ZONAL LUMEN
SUMMARY
Angle Candela
0 348
5 346
15 325
25 289
35 239
45 176
55 106
65 47
75 12
85 2
90 0
CANDLEPOWER
SUMMARY
Height fc Dia. (ft.)
4’ 22 8.0
6’ 10 12.0
8’ 5 16.0
10’ 3 20.0
CONE OF LIGHT
10 20 30 40
348
261
174
87
90
80
70
60
50
POLAR GRAPH
Spacing Avg. fc W/ft
2
4’ x 4’ 41.5 0.64
6’ x 6’ 19.4 0.30
8’ x 8’ 10.4 0.16
10’ x 10’ 6.9 0.11
10’ ceiling, Open Space: 50’ x 40’ x 10’
LLF: 1.0 Initial, 80/50/20 Reflectances, 2.5’ workplane
Spacing Avg. fc W/ft
2
4’ on ctr. 14.5 0.44
6’ on ctr. 9.9 0.30
8’ on ctr. 7.0 0.21
10’ on ctr. 5.8 0.18
10’ ceiling, Corridor: 6’ W x 100’ L
LLF: 1.0 Initial, 80/50/20 Reflectances,
Light levels on the ground
APPLICATION REFERENCE
(Corridor)
Spacing Criteria: 1.16
APPLICATION REFERENCE
(Open Space)
RS6 - 1000 Lumen
COEFFICIENTS OF UTILIZATION
NOTE: Floor Cavity Reflectance : 20%
RC 80% 70% 50% 30% 10% 0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
1 112 108 105 102 109 106 103 100 102 99 97 98 96 94 94 93 91 89
2 104 97 92 87 101 95 90 86 92 88 84 89 85 82 86 83 81 79
3 96 88 81 76 94 86 80 75 83 78 74 81 76 73 78 75 71 70
4 89 79 72 66 87 78 71 66 76 70 65 73 68 64 71 67 63 62
5 83 72 64 59 81 71 64 58 69 63 58 67 62 57 65 61 57 55
6 77 66 58 52 76 65 58 52 63 57 52 62 56 51 60 55 51 49
7 72 60 53 47 71 60 52 47 58 52 47 57 51 46 55 50 46 44
8 68 56 48 43 66 55 48 43 54 47 42 52 47 42 51 46 42 40
9 63 51 44 39 62 51 44 39 50 43 39 49 43 39 48 42 38 37
10 60 48 41 36 59 47 40 36 46 40 36 45 40 35 45 39 35 34
Zone Lumens % of Fixture
0 - 30° 405 40.6
0 - 40° 632 63.3
0 - 60° 937 93.7
0 - 90° 1000 100
ZONAL LUMEN
SUMMARY
Angle Candela
0 560
5 555
15 518
25 451
35 363
45 248
55 125
65 46
75 12
85 1
90 0
CANDLEPOWER
SUMMARY
Height fc Dia. (ft.)
4’ 35 7.3
6’ 16 11.0
8’ 9 14.7
10’ 6 18.3
CONE OF LIGHT
10 20 30 40
561
421
280
140
90
80
70
60
50
POLAR GRAPH
Spacing Avg. fc W/ft
2
4’ x 4’ 60 0.81
6’ x 6’ 28 0.38
8’ x 8’ 15 0.20
10’ x 10’ 10 0.14
10’ ceiling, Open Space: 50’ x 40’ x 10’
LLF: 1.0 Initial, 80/50/20 Reflectances, 2.5’ workplane
Spacing Avg. fc W/ft
2
4’ on ctr. 21.7 0.56
6’ on ctr. 14.7 0.38
8’ on ctr. 10.4 0.27
10’ on ctr. 8.7 0.23
10’ ceiling, Corridor: 6’ W x 100’ L
LLF: 1.0 Initial, 80/50/20 Reflectances,
Light levels on the ground
APPLICATION REFERENCE
(Corridor)
Spacing Criteria: 1.12
APPLICATION REFERENCE
(Open Space)