GE Energy NEMA 140 to 500 Frame Horizontal AC Small Industrial Motors Motor Installation And Maintenance Instructions GEI –
GEI-56128H 10 10. Space heaters should be de-energized during motor operation. 11. Check the operating current against the nameplate value.
GEI-56128H 11 F. Cleaning with Water and Detergent This method is very effective in cleaning windings when used with a low-pressure steam
GEI-56128H 12 bearing cavity and replace the bearings and grease when the motor is removed from service for maintenance or reconditioni
GEI-56128H 13 (2) Inspect the journals and polish them with crocus clothe if any scratches are detected. Do not allow any metal dust to fa
GEI-56128H 14 VII. FAILURE WARNING: An extreme overload or electrical failure may result in heating or arcing which can cause the insulation
GEI-56128H 15 X. TIGHTENING TORQUE FOR SAE HARDWARE General Notes related to fasteners: 1. Medium carbon steel fasteners per ASTM A449 Type 1. 2.
GEI-56128H 16 Typical 210 to 440 Frame Dripproof Construction
GEI-56128H 17 Typical 140 to 440 Frame TEFC Construction
GEI-56128H 18 Typical 500 Frame TEFC Construction - Ball Bearing Typical 500 Frame TEFC Construction - Sleeve Bearing
GEI-56128H 19 XI. Lubrication Guide (Excerpt from: GEK-72836E) Table 5: Motor Lubrication Guide Type of HP Lubrication Interval (Yrs.) Servic
GEI-56128H 2 Table of Contents I. General Information...
GEI-56128H 20 Document Revision History Rev # Date Author ISAAC # Description 0 09/01/99 G. Garver N/A Conversion from PageMaker 1 02/19/03 S
GEI-56128H 3 I. GENERAL INFORMATION A. How to Properly Use this Instruction Manual This installation and maintenance manual has been written to
GEI-56128H 4 C. Safety Symbols Below is a safety symbol table that identifies the safety symbols that appear in this manual and on the motors.
GEI-56128H 5 D. Description of Labels and Nameplates Motor rating and identification data are furnished on labels and nameplates. Pack
GEI-56128H 6 The bearings of grease-lubricated motors are greased at the factory with the grease cavity approximately 50% full. Rotate th
GEI-56128H 7 WARNING: Remove drain plugs from the frame or end shields of enclosed motors used outdoors or in other high moisture areas 2
GEI-56128H 8 3. For base assembly and motor mounting, the mounting bolts must be tightened to prevent changes in alignment and possible dam
GEI-56128H 9 IV. OPERATION A. Steps Prior to Starting WARNING: If the motor has been in a damp location, dry it out thoroughly before