Ambient Temperature Limits:
• StandardOperatingrange:-40°Cto+80°C(-40°Fto+176°F)
• ExtendedOperatingrange:-50°Cto+85°C(-58°Fto+185°F)
- For devices installed in hazardous area, temperature limits
depend on the marking.
-LCDdisplaymaynotbereadablebelow-15°C(+5°F)
- Beyond standard operating range, performance may be
affected
by the temperature shift.
• Storageandtransportation:-50°Cto+93°C(-58°Fto+200°F)
• Ambienttemperatureshift:±0.028%/°Coffullspan
(zero and span, over extended temperature range)
Process Temperature Limits:
• -210°Cto+450°C(-350°Fto+850°F)
Fortemperaturehigherthan+150°C(+302°F)orlowerthan
-100°C(-150°F),anextensionisrequiredbetweenthecase
and the torque tube. Note: See diagram page 12 and approval
certificates.
Specific Gravity Range:
• 0.15to1.4withastandarddisplacer
• Lowerandhigherspecificgravitieswithspecialdisplacers
(consult your local sales contact)
Electric Characteristics
Following
NAMUR NE 43:
• Normaloutputsignal:3.8to20.5mA
• Lowfailsafeoutputsignal(<3.6mA)
• Highfailsafeoutputsignal(>21mA)
Supply Voltage:
• Umin= 10VDC
• Umax=30VDC(intrinsicsafety)
• Umax=40VDCforAO_1
30VDCforAO_2(flameproofenvelope)
Supply Voltage Influence:
• 0.1μA/V
Operating Limits
Compliance with EMC Directive 2004/108/EC, including NF EN 61000-6-2, NF EN 61326-1, NF EN 61326-3-1, NF EN 61000-6-4 and
NF EN 55022 standards.
Electromagnetic Compatibility
• 10kWfor8/20μspulsewaveform
• 1.5kWfor10/1000μspulsewaveform
Over-voltage Protection (at 25°C / 77°F)
General Data
Performance Specifications
Instrument Head Alone
Instrument Head
with Torque Tube S/A
Accuracy (full span)
±0.1%
±0.5%
onrequest±0.25%
Hysteresis + Dead Zone (full span)
±0.1% ±0.3%
Repeatability (full span)
±0.1% ±0.2%
Performance at room temperature with standard displacer and specific gravity from 0.15 to 1.4 (or special displacer with equivalent sensor angle variation) within standard operating temperature range.