GE General Electric Heat Pump 5100 User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
13
1
The RAB71 or RAB77 wall case
must be properly installed per
instructions packed with the case.
2
Remove the corrugated stiffener
and the outdoor protective
panel. Use the slit in the out-
door panel as a handhold and
push out.
3
Install the exterior grille from
the room side following instruc-
tions packed with the grille.
Insulated Wall Case
This chassis is designed to be
installed in an insulated wall case.
This minimizes condensation
from forming on the room side
of the case.
The RAB71 wall case is insulated.
Insulation kit RAK901L is available
for use with RAB77 or existing
uninsulated wall cases when
needed.
Install the Wall Case
and Exterior Grille
Protective
panel
Slit
Stiffener
230/208 Volt
Universal Power Wall Plug Heater Wattage
Cord Kits Configuration Circuit Protective Device @ 230/208 Volts
RAK315 Tandem 15 Amp TD fuse or breaker 2.55/2.09 KW
RAK320 Perpendicular 20 Amp TD fuse or breaker 3.45/2.82 KW
RAK330* Large Tandem 30 Amp TD fuse or breaker 5.00/4.10 KW
230/208 Volt
Permanent Heater Wattage
Connection Kits Circuit Protective Device @ 230/208 Volts
RAK415/415L 15 Amp TD fuse or breaker 2.55/2.09 KW
RAK420/420L 20 Amp TD fuse or breaker 3.45/2.82 KW
RAK430/430L* 30 Amp TD fuse or breaker 5.00/4.10 KW
Kits ending in “L” have flexible conduit to reach from the kit to the knockout hole
(above right side inspection plate) in the RAK203 sub-base.
265 Volt
Permanent Heater Wattage
Connection Kits Circuit Protective Device @ 265 Volts
RAK515/515LF 15 Amp TD fuse 1.70 KW
RAK517/517LF 15 Amp TD fuse 3.00 KW
RAK520/520LF 20 Amp TD fuse 3.70 KW
RAK530/530LF* 30 Amp TD fuse 5.00 KW
Kits ending in “LF” have flexible conduit to reach from the kit to the knockout hole
(above right side inspection plate) in the RAK203 Sub-Base and have an Integral Fuse.
*Not recommended for use on 6000 BTUH units. (If this connection kit is used it will provide a maximum
heat of 3.45 KW at 230 volts and 3.7 KW at 265 volts.)
Power Connection
Chart
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 23 24