REQUIRED TOOLS AND ACCESSORIES
FOR INSTALLATION
2 wrenches: 1
1
8and 1
1
4
Pipe cutter
Ruler or tape measure
Cordless drill and a 3/16drill bit
(optional)
File
Emery paper
Screwdriver
For GXWH04F model, additional
installation parts may be required:
(2)
3
4 compression adapters with
brass ferrule and nut for installation
on copper plumbing—Installation Kit
available:
— Retail Part (WHKIT)
— GE Parts (WS35X10023)
UL-approved grounding clamps and
6-gauge copper grounding wire—
Installation Kit available:
— Retail Part (WHKIT)
— GE Parts (WS35X10023)
Teflon Tape
Optional accessories are available (Visa,
MasterCard or Discover cards accepted) by
visiting our Website at ge.com or from Parts and
Accessories 800.626.2002 (U.S.) or 800.663.6060
(Canada).
If unit is to be installed on plastic,
PVC or galvanized plumbing, separate
hardware must be purchased.
CONTENTS INCLUDED WITH PRODUCT
Filter housing and head
Product literature
Sediment filter FXUSC (Rev. 2)
(for GXWH20F only)
(2)
3
4
brass compression fittings with
nut and ferrule (for GXWH20F only)
Teflon tape (for GXWH20F only)
Canister wrench
Grounding clamps and wire (for
GXWH20F only)
Mounting bracket with (2) screws
Timer and batteries
1
GE SmartWater
INSTALLATION INSTRUCTIONS
Household Water Filtration Housing* — GXWH04F and GXWH20F
184D1060P002 01-08 JR 49-50202-1
ge.com
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
SAFETY PRECAUTIONS
Check with your state and local public works department
for plumbing and sanitation codes. You must follow these
guidelines as you install the Household Water Filtration
Housing. Using a qualified installer is recommended.
Be sure the water supply conforms with the
Specifications
Guidelines
. If the water supply conditions are unknown,
contact your municipal water company
.
WARNING:
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system.
I
t is highly recommended that a water shut-off valve be placed
directly upstream of your household filter.
PROPER INSTALLATION
Check with your local public works department for plumbing codes.
You must follow their guides as you install the Household Water
Filtration Housing.
Use the Household Water Filtration Housing on a potable, safe-to-
drink, home COLD water supply only. The filter cartridge will not
purify water or make unsafe water safe to drink. DO NOT use on
HOT water (100˚F max).
Protect the Household Water Filtration Housing and piping from
freezing. Water freezing in the housing will damage it.
Your Household Water Filtration Housing will withstand up to 125 psi
water pressure. If your house water supply pressure is higher than
100 psi during the day (it may reach higher levels at night), install
a pressure-reducing valve before the housing is installed.
Do not install on
HOT WATER
. The temperature of the water
supply to the Household Filtration Housing must be between the
minimum of 40
°F and the maximum of
1
00°F
. See the
Specification Guidelines
.
Do not
install the Household Water Filtration
Housing
using
copper solder fittings. The heat from the soldering process
will damage the unit. If making a soldered copper installation,
do all sweat soldering before connecting pipes to the housing.
Torch heat will damage plastic parts.
WARNING:
Discard all unused parts and packaging material
after installation. Small parts remaining after installation could
be a choke hazard.
Do not
install filter in an outside location or anywhere it will be
exposed to sunlight.
This Household Water Filtration Housing must be properly installed and located in accordance with the Installation Instructions before it is used.
The GXWH20F system using FXUSC (Rev. 2)
filter is tested and certified by NSF
International against NSF/ANSI Standard 42
for reduction of particulate Class V.
This GXWH04F is tested and certified by
NSF International against NSF/ANSI
Standard 42 for materials and structural
integrity requirements only.
COMPONENT
The FXUSC (Rev. 2) filter is tested and
certified by NSF International against
NSF/ANSI Standard 42 for materials
requirement only.
COMPONENT
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - GE SmartWater

REQUIRED TOOLS AND ACCESSORIESFOR INSTALLATION 2 wrenches: 11⁄8″ and 11⁄4″ Pipe cutter Ruler or tape measure Cordless drill and a 3/16″ drill bit(op

Page 2 - ABOUT THE FILTER CARTRIDGE

10LISTE DES PIÈCESGGXXWWHH02Node 4 0repérage Pièce noDescription F F001 WS35X10023 Pièces de raccordement — 1ou WHKIT002 WHTIMER Minuterie 1 1003 WS0

Page 3 - WARNING:

11NOTES • NOTAS

Page 4

HERRAMIENTAS Y ACCESSORIOS QUE SENECESITAN PARA LA INSTALACION 2 llaves inglesas: 11⁄8″ y11⁄4″ Cortador de tubos o sierra para metales Regla o cint

Page 5 - PARTS LIST

FILTRO Para agua filtrada. Dirige el flujo delagua a través del filtro.13LOS CARTUCHOS DEL FILTROReemplazo del cartucho del filtroUsted debería cambi

Page 6

14Sumario de la instalaciónNOTA: Asegúrese de dejar un espacio mínimo de 11⁄2″debajo del filtro para sacar el esceptáculo, para cambiar el cartucho.GX

Page 7 - LA CARTOUCHE DE FILTRATION

Instalación del cronómetro e instrucciones de aplicación Tapa del cronómetroBase del cronómetroSello del cronómetroCabeza2 baterías AAAInstalación y c

Page 8 - AVERTISSEMENT :

16LISTA DE PARTESGGXXWWHH02No. 4 0de ref. Parte No. Descriptión F F001 WS35X10023 Juego de instalación — 1o WHKIT002 WHTIMERCronómetro11003 WS03X1003

Page 9 - Installation du filtre

ABOUT THE FILTER CARTRIDGEFilter Cartridge ReplacementYou should change your filter when the water flow is noticeably reduced or at least every 3 mont

Page 10 - LISTE DES PIÈCES

3Installation OverviewNOTE: Be sure to allow a minimum space of 11⁄2″under the filter for removing the sump, to change the cartridge.GXWH04FGXWH20FRec

Page 11 - NOTES • NOTAS

4Timer Installation and Application InstructionsTimer capBlue reset buttonTimer baseTimer seatHead2 AAAbatteriesTimer battery installation and changeI

Page 12

5PARTS LISTGGXXWWHH0240Ref. No. Part No. Part Description F F001 WS35X10023 Installation Kit — 1or WHKIT002 WHTIMER Timer 1 1003 WS03X10038 O-Ring 1

Page 13 - LOS CARTUCHOS DEL FILTRO

OUTILLAGE ET ACCESSOIRES REQUISPOUR L’INSTALLATION 2 clefs : 11⁄8 po et 11⁄4 po Coupe-tuyau ou scie à métaux Mètre ruban ou mètre règle Perceuse s

Page 14 - ADVERTENCIA:

LA CARTOUCHE DE FILTRATIONRemplacement de la cartouche de filtrationOn doit changer la cartouche de filtration lorsque le débit d’eau diminue sensible

Page 15 - Instalación de la unidad

8Emplacement d’installationChoisir l’emplacement approprié comme suit : pas d’exposition au gel. pas d’exposition au rayonnement solaire direct.On r

Page 16 - LISTA DE PARTES

Capuchon de la minuterieBase de la minuterieJoint de la minuterieTête2 piles AAAInstallation et remplacement de la pile de la minuterieInsérez une piè

Comments to this Manuals