Installation
Turn off power and remove panel
from uorescent box sign.
1
Push Line Fit Light into existing
uorescent lamp holders.
5
Read the product labels to determine
Line Fit Light length required to span
width of sign based on table in the
Specications section (last page).
3
Old Fluorescent tube
F48T12HO
or F48T8HO
Remove old uorescent tubes, ballast
and wiring. DO NOT remove existing
uorescent lamp holders.
NOTE: Follow all federal and local
regulations when disposing of
neon tubing, uorescent tubes,
transformers and ballasts.
2
Remove old components
Continue installing Line Fit Light
xtures.
6
Orient Line Fit Light so LEDs are facing
front of sign, then pull and twist the
two endcap ttings so they align with
existing uorescent lamp holders.
4
LEDs face
front of sign
Pull and twist endcap
tting to align with
lamp holder
Prior to installation, survey the site for information regarding power and accessibility inside and outside the building. Ensure that the
branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have a
current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).
If removal of the existing lighting equipment (see Step 2) eliminates the disconnect switch, as required by applicable local, state, or
country electrical codes; a new disconnect switch must be installed.
If required, the disconnect switch shall be installed by qualied personnel, in accordance with applicable local, state, and country
electrical codes.
Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in all holes
0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13 mm), use an
aluminum or zinc coated steel patch with rivets and sealant.
GEF48T12xxxHOLED
New LED retrot
Components
1
1
2
2
3
3
4
4
5
5
UL certied 18 AWG (0.82 mm
2
) supply wire
UL certied 22-14 AWG (0.33-2.08 mm
2
) wire connectors
or 22-18 AWG (0.33-0.82 mm
2
) inline/IDC connectors
End caps
Tetra
®
24 Volt Power Supply
GE Line Fit Light-LED (LFL-LED) modules