8.2”
(208)
7.7”
(196)
2.2”
(56)
1.5”
(38)
2.4”
(61)
6”
(152)
LED Colorlights - Wayside
• 8 inch (200 mm) - 10V DC • 96 Series
Mechanical Outline
Dimensions in inches. (mm) indicates metric equivalent
7.7”
(196)
2.2”
(56)
1.5”
(38)
2.4”
(61)
6”
(152)
Product Information
Aspect Nominal Number
Model Number
Color Watts
1
of LEDs
Short and Mid-Range: Visibility to 2000 ft (600 m)
2
•
RM4-GSFB-28B-96GK Green 15W 90
•
RM4-YCFB-43B-96GK Yellow 18W 132
•
RM4-RSFB-43B-96GK Red 18W 132
RM4-WSFB-28B-96GK White 15W 90
Long Range: Visibility to 5000 ft (1500 m)
2
•
RM4-GSFB-75B-96G Green 15W 90
•
RM4-YCFB-85B-96G Yellow 15W 88
•
RM4-RCFB-75B-96G Red 15W 88
RM4-WSFB-75B-96G White 15W 90
Notes:
1
This is a minimum stabilized value at T = 25°C.
2
For VI Curves and Isocandella graphics, please refer to Pages 3 and 4.
3
Signal performance when exposed to external light (ex. sun, head lamp).
is dependant on each application field testing is recommended.
Distributed by:
Design Compliance
Characteristic Compliance
Impact Resistance of Front Shell IR3
Mechanical Vibration & Shock AREMA 11.5.1.D.4/D.5. Class B
Water/Dust Ingress Protection
(in typical Rail Housing)
EN 60529 IP65
Dielectric Strength AREMA 11.5.1.D.7, Class B
Electrical Surge Protection EN61000-4-5, Class 3, AREMA 11.3.3
Electromagnetic Compatibility (EMC) FCC Part 15, Subpart B
Operating Specifications
Parameter Rating
Operating Temperature Range -40 to 70°C (-40 to 158°F)
Nominal Operating Voltage 10V DC
Operating Voltage Range 8 - 16V DC
Voltage Turn-Off 3.5V DC
Turn-On/Turn-Off Time < 75ms
Typical Clamping Voltage (AREMA 11.3.3.E) 42V
Maximum Allowable Surge Voltage
and Energy Handling Capability (AREMA 11.3.3.E)
65V DC & 15J for 2ms
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3 for North America · or · + 1 . 2 1 6 . 2 6 6 . 2 4 1 9
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand and logo are trademarks of the General Electric Company.
© 2013 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
RAIL268-R070213
Comments to this Manuals