Page view 2
To power
supply
Red (+)
Black or blue (-)
Red Stripe (+)White (-)
Cap wires
Connect LED strips using in-line (IDC) connectors
or twist-on wire connectors.
Must cap all exposed wires with appropriate wire
connectors.
Run a wire from the Power Supply to each
channel letter and connect to the rst LED
module on the strip.
Must be used with Tetra
®
12 Volt Power Supplies.
1 2
3
Connect the red stripe wire (+) of the LED strip to
the red wire (+) of the power supply. Connect the
white wire (-) of the LED strip to the black or blue
wire (-) of the power supply.
NOTE: All electrical connections should be made
within the letter.
4
Power
Supply
To Tetra LED System
Red (+)
Black or blue (-)
Red stripe (+)
White (-)
Electrical Connections
Retrot Instructions
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the building. Ensure
that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have
a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or uorescent tubes; and associated
transformers and ballasts. Care should be taken not to break the existing neon or uorescent tubes.
NOTE: Follow all federal and local regulations when disposing of neon tubing, uorescent tubes, transformers and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, state, or
country electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in
all holes 0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13 mm), use an aluminum
or zinc coated steel patch with rivets and sealant.
5. (Existing Signs Only) A clean and dry mounting surface ensures optimum adhesion if the self-adhesive method of mounting is chosen. Follow
the manufacturer’s directions when using a non-oil based solvent, such as rubbing alcohol to clean the surface area where you intend to mount
the module. Before installing, ensure the surface is dry.
6. Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
7. A Tetra
®
12VDC Class 2 Power Supply, as listed below, must be used with this retrot kit. Using the Maximum Loading chart below, determine the
number of Tetra
®
Class 2 Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload
the Tetra
®
Class 2 Power Supply chosen.
8. Follow the instructions above to properly mount the LED modules.
9. Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
10. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions found in the
power supply installation guide.
11. If required, the disconnect switch shall be installed by qualied personnel, in accordance with applicable local, state, and country electrical codes.