GE SV-60 Operations Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
www.ge.com/inspectiontechnologies
System Setup and Operation
CAUTION:
1. Verify that the supply voltage is within the 100-240VAC range specified for this product.
2. To prevent temporary blinding, insert light guide into socket before turning power ON.
3. The light guide tip and light source socket will be hot when light guide is removed.
CONTROLS & PORTS
ON/OFF Switch
A two position rocker switch is used to turn the unit on or off. Depressing the side marked
with a ( I ) turns the unit on, while depressing the side marked with an ( £ ) turns it off.
Light Intensity Control Knob
This knob on the front panel rotates to adjust the amount of light transferred into the light
guide. Rotating the ring clockwise will increase the amount of light in the image and rotating
the ring counter clockwise will decrease the amount of light. This manual control is helpful
when trying to better illuminate one part of the image or when trying to reduce blooming.
Light Exit/Light Guide Socket
Socket will accept Olympus style adapter.
Video-In Camera Port
When using a borescope with the BCAM C-Mount Camera, the BCAM power/video cable con-
nects to the light source here. It carries power from the light source to the camera, and brings
the camera video back to the light source video channel. It can not be used with cameras
other than the BCAM.
Video-Out Ports
When using a borescope with the BCAM C-Mount Camera, the camera video is accessed at
either of these ports. Connect either an S-Video or composite BNC cable from the appropri-
ate output port to a monitor for display, or other peripheral device for recording.