GE masoneilan_39003_series Service Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6 | GE Oil & Gas
Numbering System
1st 2nd 1st 2nd 3rd 4th 5th
3 4 3 9 3
Actuator Type
34 Double acting or
spring return piston
actuator
Body
Series
39
Actuator Mounting
(Type 25 Only)
0. Undefined
*1. Parallel to pipe. Air to open
action.
*2. Parallel to pipe. Air to close
action.
3. Perpendicular to pipe. Air to
open action.
4. Perpendicular to pipe. Air to
close action.
5. Parallel to pipe. Air to open
action.
6. Parallel to pipe. Air to close
action.
7. Perpendicular to pipe. Air to
open action.
8. Perpendicular to pipe. Air to
close action.
Seat
Material
1. PTFE or
RTFE Seal
Ring
2. Inconel
Seal Ring
3. Fire-Safe
Seal Ring
Not Assigned
3
*Standard Actuator Mounting Arrangement