GE ISOVOLT Lynx Brochure Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
Technical Specications
ISOVOLT Lynx 160 ISOVOLT Lynx 320
High Voltage Generator
Performance
Max. Output Voltage 160 kV 320 kV
Tube Voltage
from 25 kV to 160 kV From 50 kV to 320 kV
Max. Output Current 45 mA 45 mA*
Tube Current
1 mA - 45 mA* 1 mA - 45 mA*
Max. Output Power 4 kW** 4.5 kW**
Resolution
(Voltage / Current)
0.1 kV / 0.01 mA 0.1 kV / 0.01 mA
Absolute Accuracy
(Voltage / Current)
±1,5% / < 1% ±1,5 % / < 1%
Stability
(Voltage / Current)
< 0,01% / < 0,01% *** < 0,01% / < 0,01% ***
Insulation Oil (sealed high voltage tank) Oil (sealed high voltage tank)
Interfaces
High Voltage
Connections
R24 Quick Release
Flat Socket maintenance free
(optional)
R24 Quick Release
Flat Socket maintenance free
(optional)
Signal
Door contacts, interlock,external
E-stop, additional potential-free
contacts, standard connections for
warning lamp, warning light and
cooler/chiller
Door contacts, interlock,external
E-stop, additional potential-free
contacts, standard connections for
warning lamp, warning light and
cooler/chiller
Data RS-232
USB
Ethernet
RS-232
USB
Ethernet
Dimensions
Dimensions (W x D x H) 1080 x 425 x 605 mm
(42,52” x 17,7” x 23,82”)
1080 x 425 x 870 mm
(42,52” x 17,7” x 34,25”)
Weight 120 kg (265 lb) 200 kg (441 lb)
Electrical Connection
Mains 1N PE 230V ± 10%, 50/60 Hz 1N PE 230 V ± 10%, 50/60 Hz
Installation Conditions
TN-S or TN-C according EN 32 / UL
35, power requirement 6,7 kVA,
cos Phi = 0.9-1.0
TN-S or TN-C according EN 32 / UL
35, power requirement 6,7 kVA,
cos Phi = 0.9-1.0
Environmental
Operating Temperature
Range
0°C to +40°C 0°C to +40°C
Storage Temperature
Range
-30°C to +70°C -30°C to +70°C
Certication
Certication
CE, cETLus , NFC 74100 CE, cETLus , NFC 74100
Control Module
Features Touch-resistive, color display
Desk-top housing
X-ray on/o, E-Stop, 3-position key
switch
Dimensions 390 x 240 x 120 mm
(15,35” x 9,45” x 4,72”)
1.2 kg (2.64 lb)
Remote Control
Features PC application X-ray control and
service (Win 7, Win XP)
USB to RS232 converter
Fail-Safe E-Stop Box (optional)
* 40 mA permanent operation, limited to peak operation
** Limited to tube specication, temperature and operating mode
*** At constant temperature level
1080
1235
425
604
1080
1235
868
425
1080
1235
425
604
1080
1235
868
425
ISOVOLT Lynx 160
ISOVOLT Lynx 320
Page view 6
1 2 3 4 5 6 7 8

Comments to this Manuals