9.3 Port Setup
9.3.1 Commands
Each port on the MultiLink ML1200 Managed Field Switch can be setup specific port
characteristics. The commands for setting the port characteristics are shown below.
The
device command enters the device configuration mode:
device
The
setport command configures the port characteristics:
setport port=<port#|list|range> [name=<name>] [speed=<10|100>] [duplex=<half|full>]
[auto=<enable|disable>] [flow=<enable|disable>] [bp=<enable|disable>]
[status=<enable|disable>] [lla=<enable|disable>]
The arguments for the
setport command are defined as follows:
•The
device argument sets up the MultiLink ML1200 Managed Field Switch in the
device configuration mode.
•The
name argument assigns a specific name to the port. This name is a designated
name for the port and can be a server name, user name or any other name.
•The
speed argument sets the speed to be 10 or 100 Mbps. This works only with 10/
100 ports; the value is ignored and no error shown for 10 Mbps ports.
•The
flow argument sets up flow control on the port.
•The
bp argument enables back pressure signaling for traffic congestion
management.
•The
status argument enabled/disables port operation
The show port command displays information about a specific port number.
show port[=<port number>]