GEI-M1011A !" GE Industrial Systems Installation Instructions Vertical Induction Motors High Thrust Hollow & Solid-Shaft and In-L
GEI-M1011A (Delta) Low Voltage Y (Star) High Voltage Figure 2 – Terminal Board Connections Squirrel Cage Motor With One Speed Before star
GEI-M1011A Figure 3 Cooling Coil Connection Fittings To make water connections, simply remove the pipe plugs (furnished for shipping) from b
GEI-M1011A 3. Examine the motor for loose objects or debris which may have accumulated and remove any foreign material. 4.
GEI-M1011A In addition to a daily observation of the overall condition, it is recommended that a regular inspection routine be set up to check per
GEI-M1011A Table 2 OIL VISCOSITY (For a particular motor, refer to the lubrication nameplate or instructions) Oil Viscosity – SUS Bearing Fu
GEI-M1011A To obtain optimum results, use Exxon POLYREX EM (General Electric Specification D6A2C23) polyurea grease should be used fo
GEI-M1011A above the upper bearing. This adjustment is made at the factory and need not be disturbed on a new motor. However, should the
GEI-M1011A Angular-contact bearings which are to be stacked together should have their high points of eccentricity (indicated by a burnished
GEI-M1011A Suction should be used to remove dirt and dust particles from windings to avoid driving particles into the windings and
GEI-M1011A VII. TROUBLE SHOOTING CHART Affected Parts Difficulty What to Check Windings Overheating • Calibration of measuring instrument •
GEI-M1011A Table of Contents Subject Page I. General Information...
GEI-M1011A Figure 4 213-286 Frame Motors Typical Hollow-Shaft High-Thrust, Totally Enclosed Fan Cooled Motor With Angular Contact Ball Lower T
GEI-M1011A Figure 5 324-449 Frame Motors Typical Hollow-Shaft High-Thrust, Totally Enclosed Fan Cooled Motor With Angular Contact Upper Bearing.
GEI-M1011A FIGURE 6 – 509-5011 FRAME MOTORS TYPICAL HOLLOW-SHAFT, HIGH-THRUST TEFC MOTOR WITH ANGULAR ONTACT BALL UPPER THRUST BEARING. SELF-RELEA
GEI-M1011A Figure 7 182-286 Frame Motors Typical Solid Shaft High-Thrust, Totally Enclosed Fan Cooled Motor With Angular Contact Lower Bearing.
GEI-M1011A Figure 8 324-449 Frame Motors Typical Upper Bearing And Fan Construction For TEFC Solid Shaft Motors Suitable For High Down Thrust, M
GEI-M1011A FIGURE 9 – 444-5011 FRAME MOTORS TYPICAL UPPER BEARING AND FAN CONSTRUCTION FOR SOLID-SHAFT TEFC MOTOR. HIGH UP AND DOWN THRUST CONS
GEI-M1011A FIGURE 10 TYPICAL SOLID-SHAFT, HIGH THRUST TEFC 509-5011 FRAME MOTOR WITH SPHERICAL ROLLER UPPER THRUST BEARING 26
GEI-M1011A ! General Electric Company We welcome comments and suggestions to make this publication more useful. Your Name Today’s D
GEI-M1011A ……………………………………………….…………………Fold here and close with staple or tape………………………………….…………………. Place Stamp Here GE I
GEI-M1011A Document Revision History Rev # Date Author ISAAC # Description 0 04/30/02 SL N/A New document. 1 05/21/02 LP
GEI-M1011A I. GENERAL INFORMATION A. How to Properly Use This Instruction Manual This manual has been written to assist the user with proper pr
GEI-M1011A C. Safety Precautions WARNING: High voltage and rotating parts can cause seri ous or fatal injuries. Installat
GEI-M1011A D. INTRODUCTION General Electric high thrust vertical motors covered by these instructions are carefully constructed of high qu
GEI-M1011A to prevent the entrance of moisture, dust, or dirt during storage and installation. Precautions are taken by the factory
GEI-M1011A C. Alignment of Solid Shaft Motors Accurate mechanical lineup is essential for successful operation. Mechanical vibration and
GEI-M1011A Table 1 Frame Size XH 213-215 50.8 mm (2.00 in.) 254-256 57.15 mm (2.25 in.) 284-286 63.5 mm (2.50 in.) 324-326 95.25 m
GEI-M1011A A very rapid decrease in speed can result in acceleration forces great enough to prevent the pins from dropping. This c