Documentation and recording
Store & preview a minimum of 200 user-named data sets
with A-Scans for quick recall and instrument setup.
UltraDOC 4 software program for bi-directional
communication with a PC for
easy storage of data sets with
A-scan and documentation of
test results.
UltraMATE™ software program
simplifies the transfer, storage,
analysis, and documentation
of thickness data.
Reports with A-Scans are output
directly to a variety of
printers.
Alphanumeric Thickness Datalogger for flexible, convenient
storage of thickness readings in Linear, Grid, or Custom-
Linear file structures with user-input filenames, location
I.D.’s, notes, memo, & header fields.
Range USN 60 0.040” to 1100” (1 mm to 28 m) at steel velocity;
range selectable in fixed steps or continuously
variable
Range USN 60L
range is 0.040” to 480” (1 mm to 12 m)
Material Velocity Continuously adjustable from 0.0098 to
0.6299 inches/μs (250 to 16,000 m/s);
65 selectable material velocities
Display Delay -20 to 3498 μs in steel (dependent on range)
Probe Delay/
Zero Offset
0 to 999.9 μs
Damping 50, 75, 150, 500 ohms
Gain 0 to 110 dB adjustable in selectable steps 0.1, 0.5,
1.0, 2.0, 6.0, user definable, and locked
Test Modes Pulse echo, dual, and thru-transmission
Pulser Square wave excitation pulse
Pulse Voltage
(Square wave pulser
mode)
50 to 450 V scrollable in 10 V adjustments
Pulse Width (Square
wave pulser mode)
Tunable from 50 to 1000 ns in 10 ns adjustments
Pulse Energy
(Spike mode)
Low, High
Pulse Repetition
Frequency USN 60
Autolow, autohigh, manually adjustable from 15 to
6000 Hz (spike mode) and 15 to 2000 Hz in square
wave mode, in 5 Hz increments, external trigger
(spike mode only)
Pulse Repetition
Frequency USN 60L
Limited to 2000 Hz in both spike and square wave
mode
Bandwidth
(amplifier bandpass)
0.25 to 25 MHz with 10 selectable settings including
broadband
Gate Monitors Two independent flaw gates controllable over entire
sweep range
Measurement Modes Zero-to-first, multi-echo with selectable flank or
peak detection
Rectification Positive halfwave, negative halfwave, fullwave, RF
Reject (suppression) 0 to 80% linear
Units Inch, millimeter, or microsecond selectable
Operating
Temperature
-20° to 55°C (-4° to 130°F);
-25° to 70ºC (-13° to 158 º F ) storable
Languages Selectable English, German, French, Spanish, Italian,
Portuguese, Norwegian, Swedish, Finnish, Danish,
Dutch, Russian, Czech, Romanian, Slovakian
Probe Connectors BNC or Lemo selectable at order
Keypad International symbols
Battery Power Lithium Ion battery pack;
NiMH, NiCad or alkaline cells substitutable
Battery Life 11 hours on Li-Ion battery pack
Size 11.1” W x 6.75” H x 6.25” D (282 x 171 x 159 mm)
Display 640 x 480 pixels Color LCD 132.48 x 99.36 mm
Weight 6.6 lbs. (3.0 kg) Li-Ion battery;
3.5 lbs.(1.6 kg) without battery
Color Leg Easy identification of leg and skip distances for
angle beam inspection in A-scan or grid
background colors
Weld Rating
Calculation
Simplifies the rating of weld indications according
to AWS specification D1.1, (formula D=A-B-C)
Warranty 2 year conditional warranty on parts and labor;
free 2nd year contingent upon return of unit within
13 months of purchase for recertification
Dust Proof/
DrippingWater Proof
As per IEC 529 specification for IP54 classification
Compliance EMC/EMI: EN 55011:2007, EN 61000-6-2:2005
Ultrasound: EN 12668, ASTM E317
Options
DAC / TCG Option
Multiple Curve DAC (Distance Amplitude Curve)/ TCG (Time Corrected
Gain) for echo amplitude adjustment and evaluation, 40 dB dynamic
range, 12 dB/μs slope, record up to 16 points, recorded points are
individually editable, new points can be inserted. Display four
additional curves based upon dB offset feature from originally
recorded DAC curve. TCG attenuation and transfer correction
features enable use on other materials and surface conditions.
IF (Interface) Gate Option
For automatic start of the display, Gate A, Gate B, and / or DAC / TCG
for immersion testing applications.
DGS Option
Displays a curve for a particular equivalent reflector size as a
function of the distance from the probe to the reflector for 25
narrowbanded probes. The ERS (Equivalent reflector size) function
automatically calculates the corresponding equivalent reflector
diameter in mm or inches for any echo in the measurement gate.
BEA Backwall Echo Attenuator Option
Allows independent gain control of the region under Gate B for
backwall echo monitoring.
VGA Output Option*
Provides an easy way to connect to a PC monitor or PC projector for
viewing by large audiences or training purposes.
RF Output Option*
Outputs the raw RF waveform via a standard Lemo #00 connector
for further analysis.
HiSPD High Speed Digital Output Option
Outputs amplitude or thickness values 20 times faster than RS 232
port.
* Order with new instrument only. Later upgrade not possible.