Installation Instructions
INSTALLATION INSTRUCTIONS
3. PREPARE THE AIR
CONDITIONER
A. Install the top mounting rail with Type A screws;
4 for AHM12, AHM10, AHM08 and ADH08, and
3 for AHM05 and AHM06 from the outside of
the case.
B. Apply the weather seals provided to the bottom,
top and sides of the window to the seal around
the perimeter of the air conditioner.
C. Slide the side curtain panels into the side panel
rails.
D. Slide left and right side
curtain frames into top
and bottom rails. Make
sure that side curtains snap
into side of the frames.
1. WINDOW REQUIREMENTS
These instructions are for a standard
double-hung window. You will need to modify
them for other types of windows.
The air conditioner can be installed without the
side curtain panels if needed to fit in a narrow
window. See the window opening dimensions.
All supporting parts must be secured to firm
wood, masonry or metal.
The electrical outlet must be within reach of the
power cord.
Follow the dimensions in the table and
illustration for your model.
2. STORM WINDOW
REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will
keep it from draining properly. To adjust for this,
attach a piece of wood to the sill.
WOOD PIECES
WIDTH: 2Ǝ
LENGTH: /RQJHQRXJKWRILWLQVLGHWKHZLQGRZ
frame.
THICKNESS: To determine the thickness,
SODFHDSLHFHRIZRRGRQWKHVLOOWRPDNHLWƎ
higher than the top of the storm window frame
or the vinyl frame.
Attach securely with nails or screws provided
by the installer.
A
(With side curtain panels)
B
ƎKLJKHU
than storm
window
frame
Storm window
frame
Wood
Sill
ƎKLJKHU
than vinyl frame
(on some windows)
Vinyl frame
Top mounting rail
Bottom mounting rail
CLICK
Cut and apply
weather strip to
front and bottom
edge of window
frame.
Cut and apply
weather strip to
back edge of
the window sill.
Cut and apply
a weather strip
to side of the
curtain frame
(one on each
side).
Models A B
AHM05,
AHM06
13 3/8” min 24 1/2 - 36”
AHM08 15 1/16” min 24”-38”
AHM10,
AHM12,
AHD08
15 5/8” min 26 1/8” - 37 3/4”
Page view 8