5.
System Verification
Problem? Check the following for a solution before calling our toll free
“HELP” number at 800-448-0329
The following procedure should be used to test system configuration and
identify possible system connection errors. The phone must be con
nected to the AC power supply, lines 1 and 2 must be connected to the
line 1, 2 jack, and the phone must have been programmed with an inter
com station address.
1. Press the line 1 button. The line 1 LED and speakerphone LED
should turn green and dial tone should be heard from the speaker.
2. Dial the number for line 2. A three beep call pending tone should be
heard and the LED for line 2 should rapidly flash red with the ring
signal. If the LED for line 2 does not flash then line 2 is improperly
connected to the phone.
3. If your configuration utilizes line 3 and/or line 4, repeat steps 1 and 2
substituting the respective phone number(s) in step 2.
Comments to this Manuals