28000 Series Varipak Control Valves | 3
Microflow Control Innovation
Optimized C
V
Characteristics
The VariPak valve outshines conventional microflow valves with its sup-
port of a wide range of nominal C
v
values (from 0.0016 to 3.8), using only
eight plugs and five seats.
Precise C
v
Calibration and Selection - C
V
and
F
L
Valve Sizes
Trim
No.
Flow Coefficient C
V
Critical
Flow
Factor
F
L
With Adjustable C
V
Function
Without
Adjustable
C
V
Function
.5"
(15mm)
.75"
(20mm)
1"
(25mm)
Min.
Risk-
Free
(3)
Max.
9 0.0016 0.0020 0.0024 0.0028 0.0032 0.0036
0.0040 0.0040
0.85
8 0.004 0.005 0.006 0.007 0.008 0.009
0.010 0.010
0.85
7 0.010 0.013 0.016 0.019 0.021 0.023
0.025 0.025
0.85
6 0.020 0.025 0.030 0.035 0.040 0.045
0.050 0.050
0.85
5 0.04 0.05 0.06 0.07 0.08 0.09
0.10 0.10
0.85
4 0.10 0.13 0.16 0.19 0.21 0.23
0.25 0.25
0.90
3 0.25 0.30 0.35 0.40 0.45 0.50 0.55
0.60 0.60
0.90
2 0.5 0.6 0.7 0.8 0.9 1.0 1.1
1.2 1.2
0.92
1 1.9 1.1 1.3 1.5 1.7 1.9 2.1
2.3 2.3
0.92
0 1.5 1.9 2.3 2.6 2.9 3.2 3.5
3.8 3.8
0.92
(1) Flangeless, flanged or threaded connections.
(2) Flangeless or threaded connections.
(3) The “Risk-free” setting allows for easy valve capacity adjustments in the field to meet changing service conditions.
Figure 3: Flow Coefficient Adjustment