Table 15
Air Flow Requirements
For Separately Ventilated Motors
Static Pressure
Inches of Water
AB
Base Standard Enclosed
Speed Separately Separately
Frame RPM CFM Ventilated Ventilated
2512AT, 2513AT All 380 4.85 6.1
2812AT, 2813AT All 455 4.8 5.64
A. Standard Separately Ventilated
Air in one CE opening with solid covers on other CE openings.
Standard louvered covers on DE air outlets.
B. Enclosed Separately Ventilated (Air Ducted In and Air Ducted Out)
Air in one CE opening with solid covers on other CE opening.
Air out one DE opening.
Table 16
Renewal Parts
For CD2512AT – CD2813AT Frames
Quick Kit Reference
Frame Blower Kit Blower Kit C-Face Kit ** PY Tach Kit BC Tach Kit
Series Less Filter * With Filter * 8.5” Rabbet Less Tach Less Tach
CD25XX 36A171113AAG01 36A171113AAG01 36A172476AAG01 36A171269AAG01 36A171270AAG01
CD28XX 36A171114AAG02 36A171114AAG01 36A167477AAG01 36A171269AAG01 36A171270AAG01
DC PY Tach Only DC BC-42 Tach Only DC BC-46 Tach Only
(Fits PY Kit) (Fits BC Kit) (Fits BC Kit)
50V/1000 RPM 897A594-002 50V/1000 RPM 897A590-032 50V/1000 RPM 897A591-041
100V/1000 RPM 897A594-001 100V/1000 RPM 897A590-024 100V/1000 RPM 8971591-029
Frame AN-AC Tach AN-DC Tach AN-DC Tach ANDG240A4*** ANDG240D4***
Series 45/90V/1000 RPM 20V/1000 RPM 50V/1000 RPM 240 PPR 240 PPR
CD25XX 36A167715AAG01 36A167714AAG01 36A167714ADG01 36A167712AAG04 36A167713AAG04
CD28XX 36A167715AAG01 36A167714AAG01 36A167714ADG01 36A167712AAG04 36A167713AAG04
* Blower motor is 230/460 volt AC, 3 phase, 60 hertz.
*** Requires motor disassembly by qualified service facility to install.
*** Bi-directional, dual output.