GE Washer and Dryer Specifications
For complete information see installation instructions packed with dryer.
Important note:
GE Kit Number 14-A018 needed when converting rear exhaust to bottom or side.
(On Extra-large (5.7) capacity models only.)
Ducting materials
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust
duct. If “all rigid metal” duct cannot be used, then “flexible all metal” venting can be used, but
it will reduce the maximum recommended duct length.The following kit or parts are available
from your local service organization.
Kit WX8X75—7' aluminum duct and 4' hood, short tail.
(OR individual parts):
WX8X65 7' aluminum flex duct only
WX8X58 4' clamps (2)
WX8X67 4' exhaust hood
See installation instructions for complete information.
Exhaust length calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side
or bottom of dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is
shown in the table. The maximum lengths for flexible ducts are less than for rigid duct.
See table in installation instructions. A turn of 45° or less may be ignored. Two 45° turns
within the duct length should be treated as a 90° elbow. A turn over 45° should be treated
as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts of
moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet
must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed
house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard
or moisture could cause damage. Never terminate the exhaust into a common duct or plenum
with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any other
obstruction with the opening pointed down. Other terminations, such as louvered wall boxes,
are acceptable provided they are equivalent to a 4" opening dampered wall cap.
See page 75 for warranty information.
Dryer exhausting information
Special installation requirements
Alcove or closet Installation:
If your dryer is approved for installation in an
alcove or closet, it will be stated on a label on the dryer back.
The dryer MUST be exhausted to the outdoors. See EXHAUST INFORMATION above and
installation instructions.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side
3" front and rear
Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
Closet doors must be louvered or otherwise ventilated and must contain a minimum of
60 sq. in. of open area equally distributed. If this closet contains both a washer and a
dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
The closet should be vented to the outdoors to prevent gas pocketing in case of a gas
leak in the supply line.
No other fuel-burning appliance shall be installed in the same closet with the dryer.
Bathroom or bedroom installation:
The dryer MUST be exhausted to the outdoors. See installation instructions.
The installation must conform with the local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.
Minimum clearances other than alcove or closet installations
Minimum clearances to combustible surfaces:
0" both sides
3" rear
For more information on venting kits and accessories, please call 1-800-GE-CARES.
Listed by
Underwriters
Laboratories
R
Dryer Exhausting Information—Use Metal Duct Only
Vertical and Horizontal Ducting
0 90 ft. 60 ft. 55 ft. 45 ft.
1 60 ft. 45 ft. 40 ft. 30 ft.
7.0, 6.0 and 5.8 2 45 ft. 35 ft. 30 ft. 20 ft.
Capacity Models 3 35 ft. 25 ft. 20 ft. 15 ft.
all Electric Dryers 4 25 ft. 15 ft. 15 ft. 10 ft.
0 90 ft. 60 ft. 55 ft. 45 ft.
7.0, 6.0 and 5.8 1 60 ft. 45 ft. 40 ft. 30 ft.
Capacity Models 2 45 ft. 35 ft. 30 ft. 20 ft.
all Gas Dryers 3 35 ft. 25 ft. 20 ft. 15 ft.
Spacemaker
®
Models
DSKS433EB 0 46 ft. 37 ft. 30 ft. 24 ft.
DSKS333EC 1 38 ft. 30 ft. 25 ft. 20 ft.
DSKP333EC 2 31 ft. 22 ft. 20 ft. 14 ft.
WSM2780D 3 24 ft. 15 ft. 16 ft. 10 ft.
0 56 ft. 42 ft. 30 ft. 22 ft.
1 46 ft. 36 ft. 22 ft. 14 ft.
Spacemaker Model 2 34 ft. 28 ft. 16 ft. 10 ft.
WSM2700D 3 32 ft. 18 ft. 10 ft. 5 ft.
Spacemaker Models 0 43 ft. 36 ft. 30 ft. 24 ft.
WSM2420D 1 33 ft. 26 ft. 24 ft. 18 ft.
WSM2480D 2 23 ft. 16 ft. 16 ft. 10 ft.
Number
of
90°
Turns
Maximum Length of 4"
Dia. Rigid Metal Duct
Maximum Length of 4"
Dia. Flexible Metal Duct
Exhaust Hood Type
Exhaust Hood Type
Domestic
Dryer Models
A
4" Opening
B
2-1/2"
Opening
A
4" Opening
B
2-1/2"
Opening
A
4
Best Performance
B
2-1/2
A
Page view 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 75 76

Comments to this Manuals

No comments