Installation Instructions
,QVWDOOWKHVKXWRȺYDOYHRQWKHQHDUHVWIUHTXHQWO\XVHGGULQNLQJZDWHUOLQH
1
SHUT OFF THE MAIN WATER SUPPLY
AND UNPLUG REFRIGERATOR
Turn on the nearest faucet (counterclockwise) long
enough to clear the line of water.
10
Drill a 1/4 hole in the water pipe (even if using a self-
piercing valve), using a sharp bit. Remove any burrs
resulting from drilling the hole in the pipe. Take care not
to allow water to drain into the drill. Failure to drill a
1/4 hole may result in reduced ice production or smaller
cubes.
DRILL THE HOLE FOR THE VALVE
3
)DVWHQWKHVKXWRȺYDOYHWRWKHFROGZDWHUSLSHZLWK
the pipe clamp.
Tighten the clamp screws until the sealing washer
begins to swell.
NOTE: Do not overtighten or you may crush the
tubing.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
FASTEN THE SHUTOFF VALVE
4
7
FLUSH OUT THE TUBING
Turn the main water supply on
FRXQWHUFORFNZLVHDQGÀXVKRXWWKH
tubing until the water is clear.
6KXWWKHZDWHURȺDWWKHZDWHUYDOYH
after about one quart (1 liter) of water
KDVEHHQÀXVKHGWKURXJKWKHWXELQJ
6
CONNECT THE TUBING TO THE VALVE
Place the compression nut and ferrule (sleeve) for
copper tubing onto the end of the tubing and connect
LWWRWKHVKXWRȺYDOYH
Make sure the tubing is fully inserted into the valve.
Tighten the compression nut securely.
For plastic tubing from a SmartConnect
Refrigerator
Tubing kit, insert the molded end of the tubing into
WKHVKXWRȺYDOYHDQGWLJKWHQFRPSUHVVLRQQXWXQWLOLW
is hand tight, then tighten one additional turn with a
wrench. Overtightening may cause leaks.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
Saddle-Type
6KXWRȺ9DOYH
Compression
Nut
SmartConnect
Tubing
Packing Nut
Outlet Valve
Ferrule (sleeve)
5
ROUTE THE TUBING
Route the tubing between the cold water line and the
refrigerator.
Route the tubing through a hole drilled in the wall or
ÀRRUEHKLQGWKHUHIULJHUDWRURUDGMDFHQWEDVHFDELQHW
as close to the wall as possible.
NOTE:%HVXUHWKHUHLVVXȻFLHQWH[WUDWXELQJDERXW
feet [1.82 m] coiled into 2 turns of about 10 [25 cm]
diameter) to allow the refrigerator to move out from
the wall after installation.
INSTALLING THE WATER LINE (CONT.)
1
Choose a location for the valve that is easily accessible.
It is best to connect into the side
of a vertical water pipe. When it is
necessary to connect into a horizontal
water pipe, make the connection to the
top or side, rather than at the bottom,
WRDYRLGGUDZLQJRȺDQ\VHGLPHQWIURP
the water pipe.
CHOOSE THE VALVE LOCATION
2
Washer
Inlet End
Clamp
Screw
Vertical Cold
Water Pipe
Saddle-Type
6KXWRȺ9DOYH
Pipe Clamp
Page view 9