Page 1 - Installation manual

GE Security NetworXTM Series NX-7002 GSM/GPRS module Installation manual g imagination at work

Page 2

START UP, ENROLLING AND TESTING THE NX-7002 Inserting the SIM card Note: You must be free of all static electricity when handling electr

Page 3 - CONTENTS

Enrolling the SIM card on the GSM network • Insert the SIM card. See Inserting the SIM card for more information. • Power up the NX-7002 G

Page 4 - ORDERING INFORMATION

Testing the RSSI value During the enrolling procedure, it is mandatory to check the RSSI value (signal strength) of the NX-7002 GPRS module

Page 5 - FEATURE DEFINITIONS

PROGRAMMING THE LOCATIONS LOCATION 0 MODULE MODE OF OPERATION FEATURE SELECTION (8 segments) This location contains the system characteris

Page 6

LOCATION 1 DESTINATION SELECTION FOR REPORT CONTROL 1 (1 segment) The NX-7002 contains up to six report controls. Each report control can

Page 7 - EXITING A LOCATION

LOCATION 4 EVENT SELECTION FOR REPORT CONTROL 1 BY PARTITION (16 segments, feature selection data) All events for report control 1 are en

Page 8 - Programming data

LOCATION 12 EVENT SELECTION FOR REPORT CONTROL 3 BY PARTITION (16 segments, feature selection data) All events for report control 3 are di

Page 9 - FEATURE SELECTION DATA

LOCATION 24 EVENT SELECTION FOR REPORT CONTROL 6 BY PARTITION (16 segments, feature selection data) All events for report control 6 are

Page 10 - Inserting the SIM card

LOCATION 62 NAME OF GPRS ACCESS POINT - APN, characters 33 - 48 (16 segments) See location 60. LOCATION 63 NAME OF GPRS ACCESS POINT - A

Page 11

LOCATION 144 TCP/IP 2 LINE NUMBER (4 segments) See location 141. LOCATION 145 SMS 1 ACCOUNT NUMBER (8 segments) The SIA account number u

Page 12 - Testing the RSSI value

NX-7002 Installation manual Page 2 09/02/05

Page 13 - PROGRAMMING THE LOCATIONS

LOCATION 162 TIMERS AND COUNTERS (16 segments, numerical data) Location 162 contains the duration of various system timing functions. Seg

Page 14

LOCATION 164 SMS 1 FORMAT (1 segment) The communicator format used to transmit to the SMS 1 report destination from the NX-7002 GPRS modu

Page 15

LOCATION 165 SMS 2 PHONE NUMBER (20 segments) See location 163. LOCATION 166 SMS 2 FORMAT (1 segment) See location 164. Note: By defaul

Page 16

LOCATION 174 DEVICE STATUS FLAGS (2 segments) This location contains specific status information of the GSM/GPRS module. If the option is

Page 17

NX-7002 FOR PRIMARY OR BACKUP REPORTING NX-7002 for primary reporting The NX-7002 can be configured to be the primary transmitter. In this

Page 18

The NX-7002 can be configured as the backup device of an auxiliary dialler (NX-590 TCP/IP module or NX-570 ISDN module): • Select the desi

Page 19

NX-7002 PROGRAMMING WORKSHEETS (Factory defaults are in bold italic text) LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA MODE OF OPERATIO

Page 20

LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA EVENT SELECTION FOR REPORT CONTROL 2 (BY PARTITION) Segment 1 Alarms and Restores 0-0-0-0

Page 21

LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA EVENT SELECTION FOR REPORT CONTROL 4 (BY PARTITION) Segment 1 Alarms and Restores 0-0-0-0

Page 22

LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA EVENT SELECTION FOR REPORT CONTROL 6 (BY PARTITION) Segment 1 Alarms and Restores 0-0-0-0

Page 23

CONTENTS CONTENTS ...

Page 24 - NX-7002 for backup reporting

LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA 154 20 Account number partition 1 0-0-0-0-0-0-0-0 155 20 Account number partition 2

Page 25

LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA DEVICE STATUS FLAGS (read only) Segment 1 1 On = Communication with GSM modem OK 2 On =

Page 26 - PROGRAMMING WORKSHEETS

INSTALLATION GUIDELINES • Avoid installing the module: - Where temperatures exceed 49°C or fall below 0°C. - In the immediate vicinity o

Page 27 -

NX-7002 LAYOUT AND DESCRIPTION 9 8 1 2 3 4 1 1 11 10 7 5 7 6 DESCRIPTION 1 Future use (VVMIQ) 2 SIM card holde

Page 28

TECHNICAL SPECIFICATIONS Technical specifications NX-7002 Power supply voltage 12Vdc Current consumption - Nominal 30mA at 13.8Vdc - Ma

Page 29

APPENDIX 1: REPORTING FIXED CODES IN CONTACT-ID AND SIA The table below lists the event codes sent for the following reports (if enabled) w

Page 30

REPORT CONTACT ID SIA FAIL TO CLOSE 454 CI ZONE ACTIVITY FAULT 391 NA ZONE ACTIVITY RESTORE 391 NS RF JAMMING 344 XQ RF JAMMING RE

Page 31

APPENDIX 2: OPERATOR ID CODES This appendix provides a list of operator codes and the associated operator name. Operator name Network na

Page 32 - MOUNTING THE NX-7002

Operator name Network name ID code On mobile phone Spain Vodafone Espana S.A. Vodafone 21401 E VODAF Retevision Movil S.A AMENA 21403

Page 33 - LAYOUT AND DESCRIPTION

www.gesecurity.com EMEA Distribution is a division of GE Security EMEA bvba COPYRIGHT

Page 34 - TECHNICAL SPECIFICATIONS

GENERAL INFORMATION The NX-7002 is the GPRS module that can be added to the NetworX range of panels (NX-8-EUR, NX-6-EUR and NX-4-EUR). The

Page 35

FEATURE DEFINITIONS CID Contact ID reporting protocol. CSD Circuit Switched Data. This is the communication used to upload/download data.

Page 36 - REPORT CONTACT ID SIA

SIM card PUK code See PUK code SMS Short Message Service. SMS is a service for sending short text messages to mobile phones (see locations

Page 37

PROGRAMMING HE NX-7002 GPRS MODULE Programming the NX-7002 via the LED keypad ENTERING THE PROGRAM MODE To enter the program mode, press [

Page 38

EXITING THE PROGRAM MODE When all the desired changes in programming have been made, it is time to exit the program mode. Pressing the [Exi

Page 39

Once the data is programmed, press the [*] key to enter the data and advance to the next segment of that location. After the last segment o