GE Security NetworXTM Series NX-7002 GSM/GPRS module Installation manual g imagination at work
START UP, ENROLLING AND TESTING THE NX-7002 Inserting the SIM card Note: You must be free of all static electricity when handling electr
Enrolling the SIM card on the GSM network • Insert the SIM card. See Inserting the SIM card for more information. • Power up the NX-7002 G
Testing the RSSI value During the enrolling procedure, it is mandatory to check the RSSI value (signal strength) of the NX-7002 GPRS module
PROGRAMMING THE LOCATIONS LOCATION 0 MODULE MODE OF OPERATION FEATURE SELECTION (8 segments) This location contains the system characteris
LOCATION 1 DESTINATION SELECTION FOR REPORT CONTROL 1 (1 segment) The NX-7002 contains up to six report controls. Each report control can
LOCATION 4 EVENT SELECTION FOR REPORT CONTROL 1 BY PARTITION (16 segments, feature selection data) All events for report control 1 are en
LOCATION 12 EVENT SELECTION FOR REPORT CONTROL 3 BY PARTITION (16 segments, feature selection data) All events for report control 3 are di
LOCATION 24 EVENT SELECTION FOR REPORT CONTROL 6 BY PARTITION (16 segments, feature selection data) All events for report control 6 are
LOCATION 62 NAME OF GPRS ACCESS POINT - APN, characters 33 - 48 (16 segments) See location 60. LOCATION 63 NAME OF GPRS ACCESS POINT - A
LOCATION 144 TCP/IP 2 LINE NUMBER (4 segments) See location 141. LOCATION 145 SMS 1 ACCOUNT NUMBER (8 segments) The SIA account number u
NX-7002 Installation manual Page 2 09/02/05
LOCATION 162 TIMERS AND COUNTERS (16 segments, numerical data) Location 162 contains the duration of various system timing functions. Seg
LOCATION 164 SMS 1 FORMAT (1 segment) The communicator format used to transmit to the SMS 1 report destination from the NX-7002 GPRS modu
LOCATION 165 SMS 2 PHONE NUMBER (20 segments) See location 163. LOCATION 166 SMS 2 FORMAT (1 segment) See location 164. Note: By defaul
LOCATION 174 DEVICE STATUS FLAGS (2 segments) This location contains specific status information of the GSM/GPRS module. If the option is
NX-7002 FOR PRIMARY OR BACKUP REPORTING NX-7002 for primary reporting The NX-7002 can be configured to be the primary transmitter. In this
The NX-7002 can be configured as the backup device of an auxiliary dialler (NX-590 TCP/IP module or NX-570 ISDN module): • Select the desi
NX-7002 PROGRAMMING WORKSHEETS (Factory defaults are in bold italic text) LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA MODE OF OPERATIO
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA EVENT SELECTION FOR REPORT CONTROL 2 (BY PARTITION) Segment 1 Alarms and Restores 0-0-0-0
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA EVENT SELECTION FOR REPORT CONTROL 4 (BY PARTITION) Segment 1 Alarms and Restores 0-0-0-0
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA EVENT SELECTION FOR REPORT CONTROL 6 (BY PARTITION) Segment 1 Alarms and Restores 0-0-0-0
CONTENTS CONTENTS ...
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA 154 20 Account number partition 1 0-0-0-0-0-0-0-0 155 20 Account number partition 2
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA DEVICE STATUS FLAGS (read only) Segment 1 1 On = Communication with GSM modem OK 2 On =
INSTALLATION GUIDELINES • Avoid installing the module: - Where temperatures exceed 49°C or fall below 0°C. - In the immediate vicinity o
NX-7002 LAYOUT AND DESCRIPTION 9 8 1 2 3 4 1 1 11 10 7 5 7 6 DESCRIPTION 1 Future use (VVMIQ) 2 SIM card holde
TECHNICAL SPECIFICATIONS Technical specifications NX-7002 Power supply voltage 12Vdc Current consumption - Nominal 30mA at 13.8Vdc - Ma
APPENDIX 1: REPORTING FIXED CODES IN CONTACT-ID AND SIA The table below lists the event codes sent for the following reports (if enabled) w
REPORT CONTACT ID SIA FAIL TO CLOSE 454 CI ZONE ACTIVITY FAULT 391 NA ZONE ACTIVITY RESTORE 391 NS RF JAMMING 344 XQ RF JAMMING RE
APPENDIX 2: OPERATOR ID CODES This appendix provides a list of operator codes and the associated operator name. Operator name Network na
Operator name Network name ID code On mobile phone Spain Vodafone Espana S.A. Vodafone 21401 E VODAF Retevision Movil S.A AMENA 21403
www.gesecurity.com EMEA Distribution is a division of GE Security EMEA bvba COPYRIGHT
GENERAL INFORMATION The NX-7002 is the GPRS module that can be added to the NetworX range of panels (NX-8-EUR, NX-6-EUR and NX-4-EUR). The
FEATURE DEFINITIONS CID Contact ID reporting protocol. CSD Circuit Switched Data. This is the communication used to upload/download data.
SIM card PUK code See PUK code SMS Short Message Service. SMS is a service for sending short text messages to mobile phones (see locations
PROGRAMMING HE NX-7002 GPRS MODULE Programming the NX-7002 via the LED keypad ENTERING THE PROGRAM MODE To enter the program mode, press [
EXITING THE PROGRAM MODE When all the desired changes in programming have been made, it is time to exit the program mode. Pressing the [Exi
Once the data is programmed, press the [*] key to enter the data and advance to the next segment of that location. After the last segment o