49-7419-2 04-02 JR
Air Conditioners
Safety Instructions . . . . . . . . . . .2
Operating Instructions
Controls—Dip Switches . . . . . .3–5
Controls—Terminal
Connections . . . . . . . . . . . . . .6, 7
On/Off Switch . . . . . . . . . . . . . . .8
Ventilation Control . . . . . . . . . . .8
Care and Cleaning
Air Filters . . . . . . . . . . . . . . . . . . .9
Base Pan . . . . . . . . . . . . . . . . . . .9
Exhaust Coils . . . . . . . . . . . . . . . .9
Installation Instructions
Electrical Supply . . . . . . . . .11–13
Installing the Zoneline . . . .14–21
Preparation . . . . . . . . . . . . . . . .10
Servicing . . . . . . . . . . . . . . . . . .22
Troubleshooting Tips . . . . . . .23
Normal Operating Sounds . . . .24
Consumer Support
Consumer Support . . .Back Cover
Product Registration . . . . . .25, 26
Warranty . . . . . . . . . . . . . . . . . .27
Heat/Cool and
Heat Pump Models
7500 Series
Owner’s Manual and
Installation Instructions
GEAppliances.com
Write the model and serial
numbers here:
Model # __________________
Serial #____________________
Find these numbers on a label
on the front case panel.
Zoneline
®
Vertical
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Air Conditioners

49-7419-2 04-02 JRAir ConditionersSafety Instructions . . . . . . . . . . .2Operating InstructionsControls—Dip Switches . . . . . .3–5Controls—Termi

Page 2 - WARNING!

BEFORE YOU BEGINInstallation Zoneline AirInstructions ConditionersRead these instructions completely and carefully.•IMPORTANT –Save theseinstructions

Page 3 - Controls–Dip Switches

11Installation InstructionsELECTRICAL REQUIREMENTS230/208 VOLTELECTRICAL SUPPLYTandem15 Amp230/208 volt receptacle configurationPerpendicular20 AmpLar

Page 4 - Controls–dip switches

REMOVE JUNCTION BOX COVER• Remove the junction box cover by taking out thefront two screws. 1Junction boxInstallation Instructions12DIRECT CONNECT APP

Page 5

13Installation InstructionsDIRECT CONNECT APPLICATIONSMAKE WIRE LEAD CONNECTIONS INSIDE THE JUNCTION BOX1. Make all wire connections by using appropri

Page 6 - CAUTION:

Installation Instructions14ZONELINE COMPONENTSCaseZoneline unitFront Case PanelREQUIRED ACCESSORIES(Check the “Essential Elements” label on the unit.)

Page 7 - IMPORTANT:

Installation Instructions15TYPICAL UTILITY CLOSET AND DIMENSIONS(FOR REFERENCE ONLY)Side ViewTop ViewArchitectural Louver10″ductDoor/access panel3″ mi

Page 8 - On/Off Switch

Installation Instructions16UTILITY CLOSET CONNECTION LOCATIONSIMPORTANT: Plan and locate plenum, wall plug, drain and thermostat carefully to avoid in

Page 9 - CAUTION: Do not operate the

Installation Instructions17RETURN AIR GRILLE INSTALLATION OPTIONSThe room return air grille may be installed toward the front or either side of the un

Page 10 - TOOLS YOU WILL NEED

BUILD AND INSTALL THEZONELINE BASE PLATFORM1. Construct a 231⁄4″ min. x 231⁄4″ min. square platform.NOTE: The platform must have a load-bearingcapacit

Page 11 - CONNECTIONS ONLY

INSTALL THE DRAINAn external or an internal drain must be attached tothe drain connector.External DrainAttach a 90° PVC elbow to the unit’s female 3/4

Page 12 - DIRECT CONNECT APPLICATIONS

Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions Safety InstructionsIMPORTANT SAFETY INFORMATION.READ ALL INSTRUCTIONS B

Page 13 - POWER CONNECTION CHART

INSTALL AND CONNECTTHE CASE1. Remove the front case panel and pull the unit out of the case. Place the empty case onto theplatform in the closet with

Page 14

Top ductClampCase top duct adjustingscrewsMAKE UNIT ELECTRICALCONNECTIONS1. Connect the thermostat wires to the unit and setthe dip switches to the ap

Page 15

Installation InstructionsSERVICINGWARNING: Before servicing,switch power off at the service panel and lock thearea to prevent power from being switche

Page 16

Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer SupportBefore You Call For Service… GEAppliances.comTrouble

Page 17

Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions24Normal Operating SoundsYou may hear a pinging nois

Page 18

25General Electric CompanyWarranty Registration DepartmentP.O. Box 32150Louisville, KY 40232-2150Please place in envelope and mail to:✁Cut here

Page 19

26Consumer Product Ownership RegistrationImportantMail Today!General Electric CompanyLouisville, KentuckyGEAppliances.comFirstNameMr. Ms. Mrs.

Page 20

Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support27Vertical Zoneline Warranty.For The Period Of: GE W

Page 21 - CONNECT THE TOP DUCT

Printed in ChinaConsumer Support. GE Appliances WebsiteGEAppliances.comHave a question or need assistance with your appliance? Try the GE Appliances W

Page 22 - CONNECT POWER

Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Customer Service3Controls–dip switches. GEAppliances.comThe dip swit

Page 23 - Troubleshooting Tips

Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions4Controls–dip switches.Freeze Sentinel (Requires roo

Page 24 - PROTECTION

5Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer SupportGEAppliances.comTemperature Limiting (Requires room

Page 25 - Louisville, KY 40232-2150

6Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety InstructionsControls—terminal connections.Controls–Terminal Con

Page 26 - Model Number Serial Number

Remote ThermostatThe unit will be controlled by a remotethermostat.IMPORTANT: The Zoneline thermostat connections provide 24V AC only.If using a digit

Page 27 - Vertical Zoneline Warranty

8Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety InstructionsOther features of your Zoneline.About Heat Pumps (o

Page 28 - Printed in China

Indoor/Outdoor CoilsThe exhaust coils on the Zoneline should bechecked regularly. If they are clogged with dirt orsoot, they may be professionally ste