MultiLink ML1200Managed Field SwitchInstruction ManualFirmware Revision 3.3xManual P/N: 1601-9095-A1Manual Order Code: GEK-113538Copyright © 2009 GE M
1–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1.2 Order CodesML1200 - * - * - * - * - * - * *ML120
5–28 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGIn the example below “system” module box has been
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–29Here is a list of the modules and related setting
5–30 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGIt is recommended to save the configuration (usin
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–315.5 IPv6This section explains how to access the G
5–32 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGaddresses. The scalability of multicast routing i
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–33Details of the addressing are covered by numerous
5–34 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGSyntax telnet <IPv6 address> - telnet to a
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–1Multilink ML1200Managed Field SwitchChapter 6: Access ConsiderationsDigital EnergyMultil
6–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONS6.1.3 Port Security FeatureThe por
CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–36.2 Configuring Port Security thro
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–31.3 SpecificationsPERFORMANCEFiltering / Forwarding
6–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONS• remove mac - removes specific or
CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–5To deny a mac address, use the fol
6–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONSExample 6-2 shows how to enable le
CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–7Z Disable learning on required por
6–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONSExample 6-5 illustrates these step
CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–9(such as unexpected behavior). The
6–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONSWhen the switch detects an intrus
CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–11NoteIt is assumed here that the u
6–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONS6.3 Configuring Port Security wit
CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–13Note that the screen also provide
1–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1000BASE-SX, full-duplex, multi-mode(50μm cable):...
6–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONSThere is a limitation of 200 MAC
CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–156.3.2 LogsAll events occurring on
6–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONSSeverity has one of the following
CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–17In the following example, any com
6–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONS
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–1Multilink ML1200Managed Field SwitchChapter 7: Access Using RADIUSDigital EnergyMultilin
7–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUSaccess to services that are accessible
CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–310. If the supplicant does not have th
7–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUS7.2 Configuring 802.1x through the Com
CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–5and integer values can range from 0 to
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–5POWER CONSUMPTION 35 watts worst case (for a fully l
7–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUS7.2.2 ExampleExample 7-1 demonstrates
CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–7Setting port control parameters (conti
7–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUSSetting port control parameters (conti
CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–97.3 Configuring 802.1x with EnerVista
7–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUSThe following figure illustrates the
CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–11Ensure that the port which has the RA
7–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUSThe Max Reauth column shows the permi
CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–13The port authentication characteristi
7–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUSAfter all the port characteristics ar
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 8–1Multilink ML1200Managed Field SwitchChapter 8: Access using TACACS+Digital EnergyMultili
1–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONAPPROVALSWARRANTY Three years, per UL 60950 temperat
8–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING TACACS+ CHAPTER 8: ACCESS USING TACACS+8.1.2 TACACS+ FlowTACACS works in co
CHAPTER 8: ACCESS USING TACACS+ ACCESS USING TACACS+MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 8–3FIGURE 8–2: TACACS packet formatThe
8–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING TACACS+ CHAPTER 8: ACCESS USING TACACS+8.2 Configuring TACACS+ through the
CHAPTER 8: ACCESS USING TACACS+ ACCESS USING TACACS+MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 8–5Example 8-1: Configuring TACACS+:ML1
8–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING TACACS+ CHAPTER 8: ACCESS USING TACACS+8.3 Configuring TACACS+ with EnerVis
CHAPTER 8: ACCESS USING TACACS+ ACCESS USING TACACS+MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 8–7After the configuration is completed
8–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING TACACS+ CHAPTER 8: ACCESS USING TACACS+
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–1Multilink ML1200Managed Field SwitchChapter 9: Port Mirroring and SetupDigital EnergyMul
9–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUP9.2 Port Mirroring using the
CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–39.3 Port Setup9.3.1 Commands
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–71.4 Command Line Interface Firmware1.4.1 Console Con
9–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPIn Example 9-1, ports 3 and
CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–59.3.2 Flow ControlThe flow s
9–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPBack pressure and flow contr
CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–79.3.4 Broadcast StormsOne of
9–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPThe braoadcast-protect comma
CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–99.3.5 Link Loss AlertThe GE
9–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPIt is recommended to enable
CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–119.4 Port Mirroring using En
9–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPZ Make sure the Mirror Stat
CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–13Z Select a specific port by
1–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1.4.3 Console ScreenOnce the console cable is connec
9–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUP• Port Name assigns a speci
CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–159.4.3 Broadcast StormsOne o
9–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPSee details in Broadcast St
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–1Multilink ML1200Managed Field SwitchChapter 10: VLANDigital EnergyMultilinVLAN10.1 VLAN
10–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANThe following figure illustrates a VLAN as two separate broadcast
CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–3If VLANs are entirely separate segments or traffic domains - how c
10–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLAN802.1Q VLANs aren't limited to one switch. VLANs can span man
CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–510.2 Configuring Port VLANs through the Command Line Interface10.2
10–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANstart vlan=<name|number|list|range>To save VLAN configuratio
CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–710.3 Configuring Port VLANs with EnerVista Secure Web Management s
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–9NoteIf the ML1200 is not connected to a network, the
10–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANThe currently assigned Port VLANs are displayed as follows: Z Sele
CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–9As discussed above, ports 1, 2, 3, 5, 6, 7, and 8 still belong to
10–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANAfter adding the VLAN, the VLAN is not active. Activating the VLA
CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–11After activation, note that ports 1 to 3 belong to the new VLAN.
10–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLAN10.4 Configuring Tag VLANs through the Command Line Interface10.4
CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–1310.4.3 ExampleIn the following example, we start with Port VLAN a
10–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANExample 10-1: Converting Port VLAN to Tag VLANML1200#vlan type=po
CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–15Converting Port VLAN to Tag VLAN (continued)VLAN ID: 1Name : Defa
10–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANConverting Port VLAN to Tag VLAN (continued)VLAN ID: 1Name : Defa
CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–17Converting Port VLAN to Tag VLAN (continued)---------------------
1–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONZ Follow the steps described above for connecting t
10–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANConverting Port VLAN to Tag VLAN (continued)---------------------
CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–1910.5 Configuring Tag VLANs with EnerVista Secure Web Management s
10–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANThe next step is to define the VLANs needed. To do that, Z Click
CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–21• VLAN 30, Marketing VLAN - ports 5, 6 (note that port 5 belongs
10–22 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANZ Repeat the last two steps for each of the ports and each of the
CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–23To activate the VLAN, Z Click on the Status button under the Conf
10–24 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANTo enable the filter capability for each port, use the Configurat
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 11–1Multilink ML1200Managed Field SwitchChapter 11: VLAN Registration over GARPDigital Ener
11–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN REGISTRATION OVER GARP CHAPTER 11: VLAN REGISTRATION OVER GARPNoteThere must be on
CHAPTER 11: VLAN REGISTRATION OVER GARP VLAN REGISTRATION OVER GARPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 11–311. Port 2 receives
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–11ML1200# show setupVersion: ML1200 build 2.1.0 Nov 1
11–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN REGISTRATION OVER GARP CHAPTER 11: VLAN REGISTRATION OVER GARP• Send VLAN advertis
CHAPTER 11: VLAN REGISTRATION OVER GARP VLAN REGISTRATION OVER GARPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 11–5The unknown VLAN par
11–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN REGISTRATION OVER GARP CHAPTER 11: VLAN REGISTRATION OVER GARPThe time-to-live for
CHAPTER 11: VLAN REGISTRATION OVER GARP VLAN REGISTRATION OVER GARPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 11–711.2 Configuring GVR
11–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN REGISTRATION OVER GARP CHAPTER 11: VLAN REGISTRATION OVER GARPExample 11-2: Config
CHAPTER 11: VLAN REGISTRATION OVER GARP VLAN REGISTRATION OVER GARPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 11–911.3 Configuring GVR
11–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN REGISTRATION OVER GARP CHAPTER 11: VLAN REGISTRATION OVER GARP
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–1Multilink ML1200Managed Field SwitchChapter 12: Spanning Tree Protocol (STP)Digital Ene
12–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)While allowing onl
CHAPTER 12: SPANNING TREE PROTOCOL (STP) SPANNING TREE PROTOCOL (STP)MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–312.2 Configuring S
These instructions do not purport to cover all details or variations in equipment nor provide for everypossible contingency to be met in connection wi
1–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1.4.8 User ManagementA maximum of five users can be
12–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)forwarding state.
CHAPTER 12: SPANNING TREE PROTOCOL (STP) SPANNING TREE PROTOCOL (STP)MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–5• Priority: STP us
12–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)Example 12-3 shows
CHAPTER 12: SPANNING TREE PROTOCOL (STP) SPANNING TREE PROTOCOL (STP)MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–7priority [port=<
12–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)Example 12-4: Conf
CHAPTER 12: SPANNING TREE PROTOCOL (STP) SPANNING TREE PROTOCOL (STP)MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–9Configuring STP pa
12–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)Configuring STP p
CHAPTER 12: SPANNING TREE PROTOCOL (STP) SPANNING TREE PROTOCOL (STP)MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–11Configuring STP p
12–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)Configuring STP p
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–1Multilink ML1200Managed Field SwitchChapter 13: Rapid Spanning Tree ProtocolDigital Ene
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–131.4.9 HelpTyping the help command lists the command
13–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOL• STP relays confi
CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–31. Under some circ
13–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOL13.2 Configuring R
CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–5The variables list
13–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOL• Bridge Max Age:
CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–7• Path Cost: This
13–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLThe show-timers co
CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–9Example 13-4: Conf
13–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLConfiguring RSTP
CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–11Configuring RSTP
1–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION?alarmclearenableexithelplogoutpingsetshowtelnetter
13–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLConfiguring RSTP
CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–1313.2.2 Smart RSTP
13–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLromode <enable
CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–1513.3 Configuring
13–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOL• Status: Indicat
CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–17Once again, if yo
13–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLThe port specific
CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–19• P2P Ports: set
13–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLTo configure ring
CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–21Z Once in Edit m
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–151.5 EnerVista Secure Web Management1.5.1 Logging in
13–22 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLNoteOnly 2 ports
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–1Multilink ML1200Managed Field SwitchChapter 14: Quality of ServiceDigital EnergyMultili
14–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICETo make the preemptive queuing possibl
CHAPTER 14: QUALITY OF SERVICE QUALITY OF SERVICEMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–3FIGURE 14–2: IP Precedence ToS Field i
14–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICE14.2 Configuring QoS through the Comma
CHAPTER 14: QUALITY OF SERVICE QUALITY OF SERVICEMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–5The show qos command displays the QoS
14–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICE14.2.2 ExampleThe following example sh
CHAPTER 14: QUALITY OF SERVICE QUALITY OF SERVICEMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–7Configuring QoS (continued)ML1200(qos)
14–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICEConfiguring QoS (continued)Port priori
CHAPTER 14: QUALITY OF SERVICE QUALITY OF SERVICEMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–914.3 Configuring QoS with EnerVista Se
1–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONFIGURE 1–3: Login screenFor the first time, Z Login
14–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICEZ Select the Port and the type of QoS
CHAPTER 14: QUALITY OF SERVICE QUALITY OF SERVICEMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–11Next, a tag-based QoS is enabled on p
14–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICEIn the following window, a ToS is ena
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–1Multilink ML1200Managed Field SwitchChapter 15: IGMPDigital EnergyMultilinIGMP15.1 Over
15–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMPzero. On the other hand, a transient group is dynamically assigned
CHAPTER 15: IGMP IGMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–3The figure below shows a network running IGMP.FIGURE 15–1: Advanta
15–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMPEither of these switches can operate as querier because a multicas
CHAPTER 15: IGMP IGMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–515.1.4 Reserved Addresses Excluded from IP Multicast (IGMP) Filter
15–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMP15.2 Configuring IGMP through the Command Line Interface15.2.1 Com
CHAPTER 15: IGMP IGMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–7show-groupThe following command sequence illustrates how to displa
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–17FIGURE 1–4: Welcome screen1.5.2 Privilege Levels• O
15–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMP15.2.2 ExampleThe following example shows how to configure IGMP.Ex
CHAPTER 15: IGMP IGMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–9Configuring IGMP (continued)ML1200(igmp)## set-leave enableIGMP im
15–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMPConfiguring IGMP (continued)ML1200(igmp)## show igmpIGMP State :
CHAPTER 15: IGMP IGMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–1115.3 Configuring IGMP with EnerVista Secure Web Management softwa
15–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMPZ Click on the Edit button to edit the IGMP parameters. This scre
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–1Multilink ML1200Managed Field SwitchChapter 16: SNMPDigital EnergyMultilinSNMP16.1 Over
16–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPauthoritative. When an SNMP message does not expect a response, th
CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–3• SNMP user - A person for which an SNMP management operation is p
16–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMP• RFC 1907, Management Information Base for Version 2 of the Simpl
CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–516.2 Configuring SNMP through the Command Line Interface16.2.1 Com
1–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONIn the following example below, the user peter was
16–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPtrap <add|delete> id=<id> [type=<v1|v2|inform>]
CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–7Example 16-1: Configuring SNMPML1200# set snmp type=v1SNMP version
16–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPConfiguring SNMP (continued)ML1200(snmpv3)## trap add id=1 type=v1
CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–9Configuring SNMP (continued)ML1200(snmpv3)## show-groupID Group Na
16–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPConfiguring SNMP (continued)ML1200(snmpv3)## show-accessID View N
CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–1116.3 Configuring SNMP with EnerVista Secure Web Management softwa
16–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPThe following window illustrates changes to the SNMP community pa
CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–13Z When done adding stations, click OK.Z When adding SNMP trap rec
16–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPNote the different types of trap receivers added.Stations can be
CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–1516.4 Configuring RMON16.4.1 DescriptionThe switch supports RMON (
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–19After successfully adding a user, the added user is
16–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPML1200(rmon)## show rmon eventRMON Event Default Owner : testRMON
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–1Multilink ML1200Managed Field SwitchChapter 17: Miscellaneous Digital EnergyMultilinMis
17–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDS• SMTP alerts can be enabled o
CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–3The delete command deletes the
17–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDSExample 17-1: Configuring SMTP
CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–517.2 Statistics17.2.1 Viewing
17–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDSThe following figure displays
CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–717.3 Serial Connectivity17.3.1
17–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDS17.4 History17.4.1 CommandsThe
CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–917.5 Ping17.5.1 Ping through t
1–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONThe firmware will prompt to verify the delete comma
17–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDS17.6 Prompt17.6.1 Changing th
CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–1117.7 System Events17.7.1 Desc
17–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDSEvent logs can be exported to
CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–13For viewing each specific log
17–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDS17.8 Command Reference17.8.1
CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–15• show smtp: displays e-mail
17–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDS• save •whoami: display the u
CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–17• portaccess •reauth •setport
17–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDSThe port mirroring commands a
CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–19The Simple Mail Transfer Prot
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–21After clicking on the edit icon, the screen opens u
17–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDSThe VLAN commands are shown b
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–1Multilink ML1200Managed Field SwitchChapter 18: Modbus ProtocolDigital EnergyMultilinMo
18–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOLThe commands enable the Modbus protocol and
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–318.1.3 EnerVista SettingsTo modify the Modbu
18–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL18.2 Memory Mapping18.2.1 Modbus Memory MapT
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–50062 Port 13 type 0 to 6 1 F4 Varies0063 Por
18–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0090 Port 27 link status 0 to 1 1 F3 00091 P
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–700BE Port 9 activity 0 to 1 1 F3 000BF Port
18–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL00F0 Port 1: Number of late collisions occur
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–90128 Port 2: Number of 128 to 255 byte frame
TOC TABLE OF CONTENTSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL TOC–ITable of Contents1: INTRODUCTION GETTING STARTED ...
1–22 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1.5.5 HelpHelp for the EnerVista Secure Web Managem
18–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0160 Port 3: Number of 1023 to maximum byte
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–110198 Port 4: Number of multicast frames sen
18–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL01D0 Port 6: Number of bytes received 0 to
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–130208 Port 7: Number of frames sent 0 to 429
18–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0240 Port 8: Number of broadcast frames rec
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–150278 Port 9: Number of oversized frames rec
18–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL02B0 Port 10: Number of collisions occurred
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–1702E8 Port 11: Number of 65 to 127 byte fram
18–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0320 Port 12: Number of 512 to 1023 byte fr
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–190358 Port 13: Number of dropped received pa
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–23Z Confirm the logout by selecting OK in the pop-up
18–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0390 Port 14: Number of <64 byte fragmen
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–2103C8 Port 16: Number of frames received 0 t
18–22 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0400 Port 17: Total frames received 0 to 42
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–230438 Port 18: Number of frames with CRC err
18–24 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0470 Port 19: Number of jabber frames recei
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–2504A8 Port 20: Number of 64-byte frames rece
18–26 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL04E0 Port 21: Number of 256 to 511 byte fra
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–270518 Port 22: Number of MAC error packets 0
18–28 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0550 Port 23: Number of broadcast frames se
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–290588 Port 25: Number of bytes sent 0 to 429
1–24 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1.6 ML1200 Firmware Updates1.6.1 Updating Multilink
18–30 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL05C0 Port 26: Total bytes received 0 to 429
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–3105F8 Port 27: Number of multicast frames re
18–32 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0630 Port 28: Number of bad fragments recei
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–330668 Port 29: Number of late collisions occ
18–34 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL06A0 Port 30: Number of 128 to 255 byte fra
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–3506D8 Port 31: Number of 1023 to maximum byt
18–36 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0710 Port 32: Number of multicast frames se
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–3718.2.2 Format Codes• Bitmap: 32-bit group o
18–38 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL A–1Multilink ML1200Managed Field SwitchAppendix ADigital EnergyMultilinAppendix AA.1 Revisi
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–25Z Save the existing configuration (refer to section
A–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALAPPENDIX A CHAPTER A: APPENDIX AA.2 WarrantyA.2.1 GE Multilin Warranty StatementGeneral
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL B–1Multilink ML1200Managed Field SwitchAppendix B: DC Power InputDigital EnergyMultilinDC P
B–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALDC POWER INPUT CHAPTER B: DC POWER INPUTB.1 Specifications for Multilink ML1200 Switches
CHAPTER B: DC POWER INPUT DC POWER INPUTMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL B–3B.2 -48 V DC, 24 V DC and 125 V DC Power, Theory
B–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALDC POWER INPUT CHAPTER B: DC POWER INPUTB.3 Applications for DC Powered Ethernet Switche
CHAPTER B: DC POWER INPUT DC POWER INPUTMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL B–5B.4 ML1200, -48 V, 24 V, 125 V DC InstallationTh
B–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALDC POWER INPUT CHAPTER B: DC POWER INPUTB.5 UL Requirements for DC-powered units48VDC pr
CHAPTER B: DC POWER INPUT DC POWER INPUTMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL B–7B.6 OperationOperation of Multilink ML1200 Switc
B–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALDC POWER INPUT CHAPTER B: DC POWER INPUT
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL C–1Multilink ML1200Managed Field SwitchAppendix C: Internal DC Dual-Source Power Input Digi
1–26 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONZ Once the file transfer is completed reboot the sw
C–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTERNAL DC DUAL-SOURCE POWER INPUT OPTION CHAPTER C: INTERNAL DC DUAL-SOURCE POWER INPU
CHAPTER C: INTERNAL DC DUAL-SOURCE POWER INPUT OPTION INTERNAL DC DUAL-SOURCE POWER INPUT OPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MA
C–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTERNAL DC DUAL-SOURCE POWER INPUT OPTION CHAPTER C: INTERNAL DC DUAL-SOURCE POWER INPU
CHAPTER C: INTERNAL DC DUAL-SOURCE POWER INPUT OPTION INTERNAL DC DUAL-SOURCE POWER INPUT OPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MA
C–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTERNAL DC DUAL-SOURCE POWER INPUT OPTION CHAPTER C: INTERNAL DC DUAL-SOURCE POWER INPU
CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–27Z Reboot the switch when the transfer is complete.
1–28 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–1Multilink ML1200Managed Field SwitchChapter 2: Product DescriptionDigital EnergyMultilin
2–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTIONpoints, IP phones) that comply with th
CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–32.1.1 Four-port SFF fiber modules (CC
TOC–II MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALTABLE OF CONTENTSALARM CONTACTS FOR MONITORING INTERNAL POWER, AND SOFTWARE TRAPS .
2–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTION2.1.2 Four-Port Copper Module, C1 Modu
CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–5The LEDs on C2 PoE modules are slightl
2–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTION2.1.6 SFP Gigabit (1000Mbps) port modu
CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–72.1.8 Frame Buffering and Flow Control
2–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTION2.2 Features and Benefits• Managed swi
CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–9QoS, Port- and tag-based VLANs, GVRP,
2–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTION2.3 ApplicationsMultilink ML1200 Fiel
CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–11Extended temperature ratings and a va
2–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTIONThe ML1200 Managed Fiber with the Rin
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 3–1Multilink ML1200Managed Field SwitchChapter 3: InstallationDigital EnergyMultilinInstal
TOC TABLE OF CONTENTSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL TOC–IIISECURITY LOGS ...
3–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINSTALLATION CHAPTER 3: INSTALLATION3.2 Connecting Ethernet MediaThe Multilink ML1200 Sw
CHAPTER 3: INSTALLATION INSTALLATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 3–33.2.0.2 Connecting Fiber Optic SC-type, "Snap-I
3–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINSTALLATION CHAPTER 3: INSTALLATION3.2.0.5 Connecting Twisted Pair (CAT5e or better, Un
CHAPTER 3: INSTALLATION INSTALLATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 3–53.2.0.7 Connecting Fiber Optic Cable to SFP Transcei
3–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINSTALLATION CHAPTER 3: INSTALLATION3.3 Mechanical Installation3.3.1 DIN-Rail Mounting t
CHAPTER 3: INSTALLATION INSTALLATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 3–7For best cooling of the ML1200, attach the metal bra
3–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINSTALLATION CHAPTER 3: INSTALLATION3.4 Electrical Installation3.4.1 Powering the Multil
CHAPTER 3: INSTALLATION INSTALLATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 3–9The Alarm Contacts are on the front left area (next
3–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINSTALLATION CHAPTER 3: INSTALLATION3.4.4 Connecting a Management Console Terminal to M
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–1Multilink ML1200Managed Field SwitchChapter 4: OperationDigital EnergyMultilinOper ation
TOC–IV MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALTABLE OF CONTENTSWEB MANAGEMENT SOFTWARE ...
4–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION4.1.1.2 Address LearningAll Multilink ML1200 units have ad
CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–3The auto-negotiation logic will attempt to operate in desc
4–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION4.1.5 Power Budget Calculations for ML1200 PM’s with Fiber
CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–5Note* The use of either multi-mode or single-mode fiber to
4–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION4.2 Multilink ML1200 Managed Field Switch Port ModulesThis
CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–7Multilink ML1200 Managed Switch, the copper port supports
4–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION4.2.2.4 CB Module, 2 Ports @100Mbps single-mode FX-SC-type
CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–9Each port has an Activity (ACT) LED indicating packets bei
4–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATIONThe cable end is a “plug-in” connector with both fiber st
CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–11Each port has an Activity (ACT) LED indicating packets be
TOC TABLE OF CONTENTSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL TOC–VDESCRIPTION ...
4–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION• In the case where the 48VDC power in not internally con
CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–13described in this section or if the Multilink ML1200 Swit
4–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–1Multilink ML1200Managed Field SwitchChapter 5: IP AddressingDigital EnergyMultilinIP Add
5–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGZ Edit the IP address information.Besides manually
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–35.2 Importance of an IP Address5.2.1 DHCP and boot
5–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGThe bootimg argument is only valid with the bootp
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–5Z After the changes are completed for each section
5–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGThe show console command can show the status of th
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–7For example:ML1200# userML1200(user)## useraccess
TOC–VI MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALTABLE OF CONTENTSMAIN COMMANDS ...
5–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSING5.3 Setting Parameters5.3.1 Setting Serial Port Pa
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–9ML1200# show sysconfigSystem Name: ML1200System Co
5–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGTo set the time to be 08:10 am in the -5 hours fr
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–11To set the SNTP server to be 3.94.210.5 (with a t
5–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGAfter the proper SNTP values are entered, click O
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–13The Time Out value is in seconds. Note the time s
5–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSING5.4 System Configuration5.4.1 Saving and Loading
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–15Using Config Download, examination of the content
5–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGFIGURE 5–1: Contents of a config fileNote1. A con
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–175.4.3 Displaying configurationUsing SWM, the need
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–1Multilink ML1200Managed Field SwitchChapter 1: IntroductionDigital EnergyMultilinIntrodu
5–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGFIGURE 5–2: ’show config’ command output# System
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–19FIGURE 5–3: Displaying specific modules using the
5–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGFIGURE 5–4: Displaying configuration for differen
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–21Additional capabilities have been added to save a
5–22 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSING5.4.5 Script FileScript file is a file containing
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–23In the above example, note that all the commands
5–24 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGThis process can also be used to update new softw
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–25Z If the changes need to be ignored, click on Can
5–26 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGZ To add a host, click the Add button.Z Fill in a
CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–27Z To delete or edit the entries, use the delete o