MultiLink ML1200Managed Field SwitchInstruction ManualFirmware Revision 3.3xManual P/N: 1601-9095-A1Manual Order Code: GEK-113538Copyright © 2009 GE M

Page 2

1–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1.2 Order CodesML1200 - * - * - * - * - * - * *ML120

Page 3 - Table of Contents

5–28 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGIn the example below “system” module box has been

Page 4 - TABLE OF CONTENTS

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–29Here is a list of the modules and related setting

Page 5 - TOC TABLE OF CONTENTS

5–30 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGIt is recommended to save the configuration (usin

Page 6

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–315.5 IPv6This section explains how to access the G

Page 7

5–32 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGaddresses. The scalability of multicast routing i

Page 8

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–33Details of the addressing are covered by numerous

Page 9 - Chapter 1: Introduction

5–34 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGSyntax telnet <IPv6 address> - telnet to a

Page 10 - 1.2 Order Codes

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–1Multilink ML1200Managed Field SwitchChapter 6: Access ConsiderationsDigital EnergyMultil

Page 11 - 1.3 Specifications

6–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONS6.1.3 Port Security FeatureThe por

Page 12

CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–36.2 Configuring Port Security thro

Page 13

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–31.3 SpecificationsPERFORMANCEFiltering / Forwarding

Page 14 - Made in USA

6–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONS• remove mac - removes specific or

Page 15 - 1.4.2 Console Setup

CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–5To deny a mac address, use the fol

Page 16 - 1.4.3 Console Screen

6–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONSExample 6-2 shows how to enable le

Page 17

CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–7Z Disable learning on required por

Page 18

6–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONSExample 6-5 illustrates these step

Page 19 - 1.4.7 Privilege Levels

CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–9(such as unexpected behavior). The

Page 20 - 1.4.8 User Management

6–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONSWhen the switch detects an intrus

Page 21 - 1.4.9 Help

CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–11NoteIt is assumed here that the u

Page 22 - 1.4.10 Exiting

6–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONS6.3 Configuring Port Security wit

Page 23

CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–13Note that the screen also provide

Page 24 - FIGURE 1–3: Login screen

1–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1000BASE-SX, full-duplex, multi-mode(50μm cable):...

Page 25 - 1.5.3 User Management

6–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONSThere is a limitation of 200 MAC

Page 26

CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–156.3.2 LogsAll events occurring on

Page 27

6–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONSSeverity has one of the following

Page 28

CHAPTER 6: ACCESS CONSIDERATIONS ACCESS CONSIDERATIONSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 6–17In the following example, any com

Page 29

6–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS CONSIDERATIONS CHAPTER 6: ACCESS CONSIDERATIONS

Page 30 - 1.5.6 Exiting

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–1Multilink ML1200Managed Field SwitchChapter 7: Access Using RADIUSDigital EnergyMultilin

Page 31

7–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUSaccess to services that are accessible

Page 32 - 1.6 ML1200 Firmware Updates

CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–310. If the supplicant does not have th

Page 33 - ML1200# xmodem get type=app

7–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUS7.2 Configuring 802.1x through the Com

Page 34

CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–5and integer values can range from 0 to

Page 35

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–5POWER CONSUMPTION 35 watts worst case (for a fully l

Page 36

7–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUS7.2.2 ExampleExample 7-1 demonstrates

Page 37

CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–7Setting port control parameters (conti

Page 38

7–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUSSetting port control parameters (conti

Page 39

CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–97.3 Configuring 802.1x with EnerVista

Page 40

7–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUSThe following figure illustrates the

Page 41

CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–11Ensure that the port which has the RA

Page 42

7–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUSThe Max Reauth column shows the permi

Page 43

CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–13The port authentication characteristi

Page 44 - 2.2 Features and Benefits

7–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING RADIUS CHAPTER 7: ACCESS USING RADIUSAfter all the port characteristics ar

Page 45

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 8–1Multilink ML1200Managed Field SwitchChapter 8: Access using TACACS+Digital EnergyMultili

Page 46 - 2.3 Applications

1–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONAPPROVALSWARRANTY Three years, per UL 60950 temperat

Page 47

8–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING TACACS+ CHAPTER 8: ACCESS USING TACACS+8.1.2 TACACS+ FlowTACACS works in co

Page 48

CHAPTER 8: ACCESS USING TACACS+ ACCESS USING TACACS+MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 8–3FIGURE 8–2: TACACS packet formatThe

Page 49 - Chapter 3: Installation

8–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING TACACS+ CHAPTER 8: ACCESS USING TACACS+8.2 Configuring TACACS+ through the

Page 50 - 3.2 Connecting Ethernet Media

CHAPTER 8: ACCESS USING TACACS+ ACCESS USING TACACS+MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 8–5Example 8-1: Configuring TACACS+:ML1

Page 51 - Media IEEE Standard Connector

8–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING TACACS+ CHAPTER 8: ACCESS USING TACACS+8.3 Configuring TACACS+ with EnerVis

Page 52

CHAPTER 8: ACCESS USING TACACS+ ACCESS USING TACACS+MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 8–7After the configuration is completed

Page 53

8–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALACCESS USING TACACS+ CHAPTER 8: ACCESS USING TACACS+

Page 54 - 3.3 Mechanical Installation

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–1Multilink ML1200Managed Field SwitchChapter 9: Port Mirroring and SetupDigital EnergyMul

Page 55

9–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUP9.2 Port Mirroring using the

Page 56 - 3.4 Electrical Installation

CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–39.3 Port Setup9.3.1 Commands

Page 57

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–71.4 Command Line Interface Firmware1.4.1 Console Con

Page 58 - Console Port)

9–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPIn Example 9-1, ports 3 and

Page 59 - Chapter 4: Operation

CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–59.3.2 Flow ControlThe flow s

Page 60 - 4.1.2 Status LEDs

9–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPBack pressure and flow contr

Page 61

CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–79.3.4 Broadcast StormsOne of

Page 62

9–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPThe braoadcast-protect comma

Page 63

CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–99.3.5 Link Loss AlertThe GE

Page 64 - 4.2.2 ML1200 Modules

9–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPIt is recommended to enable

Page 65

CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–119.4 Port Mirroring using En

Page 66

9–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPZ Make sure the Mirror Stat

Page 67

CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–13Z Select a specific port by

Page 68

1–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1.4.3 Console ScreenOnce the console cable is connec

Page 69

9–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUP• Port Name assigns a speci

Page 70

CHAPTER 9: PORT MIRRORING AND SETUP PORT MIRRORING AND SETUPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 9–159.4.3 Broadcast StormsOne o

Page 71

9–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPORT MIRRORING AND SETUP CHAPTER 9: PORT MIRRORING AND SETUPSee details in Broadcast St

Page 72

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–1Multilink ML1200Managed Field SwitchChapter 10: VLANDigital EnergyMultilinVLAN10.1 VLAN

Page 73 - Chapter 5: IP Addressing

10–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANThe following figure illustrates a VLAN as two separate broadcast

Page 74

CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–3If VLANs are entirely separate segments or traffic domains - how c

Page 75 - 5.2.2 bootp Database

10–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLAN802.1Q VLANs aren't limited to one switch. VLANs can span man

Page 76

CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–510.2 Configuring Port VLANs through the Command Line Interface10.2

Page 77 - 5.2.4 Using Telnet

10–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANstart vlan=<name|number|list|range>To save VLAN configuratio

Page 78 - ML1200# show console

CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–710.3 Configuring Port VLANs with EnerVista Secure Web Management s

Page 79

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–9NoteIf the ML1200 is not connected to a network, the

Page 80 - 5.3 Setting Parameters

10–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANThe currently assigned Port VLANs are displayed as follows: Z Sele

Page 81 - 5.3.3 Date and Time

CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–9As discussed above, ports 1, 2, 3, 5, 6, 7, and 8 still belong to

Page 82 - 5.3.4 Network Time

10–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANAfter adding the VLAN, the VLAN is not active. Activating the VLA

Page 83

CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–11After activation, note that ports 1 to 3 belong to the new VLAN.

Page 84

10–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLAN10.4 Configuring Tag VLANs through the Command Line Interface10.4

Page 85

CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–1310.4.3 ExampleIn the following example, we start with Port VLAN a

Page 86 - 5.4 System Configuration

10–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANExample 10-1: Converting Port VLAN to Tag VLANML1200#vlan type=po

Page 87

CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–15Converting Port VLAN to Tag VLAN (continued)VLAN ID: 1Name : Defa

Page 88

10–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANConverting Port VLAN to Tag VLAN (continued)VLAN ID: 1Name : Defa

Page 89

CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–17Converting Port VLAN to Tag VLAN (continued)---------------------

Page 90

1–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONZ Follow the steps described above for connecting t

Page 91

10–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANConverting Port VLAN to Tag VLAN (continued)---------------------

Page 92 - 5.4.4 Saving Configuration

CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–1910.5 Configuring Tag VLANs with EnerVista Secure Web Management s

Page 93

10–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANThe next step is to define the VLANs needed. To do that, Z Click

Page 94 - 5.4.5 Script File

CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–21• VLAN 30, Marketing VLAN - ports 5, 6 (note that port 5 belongs

Page 95

10–22 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANZ Repeat the last two steps for each of the ports and each of the

Page 96

CHAPTER 10: VLAN VLANMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 10–23To activate the VLAN, Z Click on the Status button under the Conf

Page 97 - 5.4.7 Host Names

10–24 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN CHAPTER 10: VLANTo enable the filter capability for each port, use the Configurat

Page 98

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 11–1Multilink ML1200Managed Field SwitchChapter 11: VLAN Registration over GARPDigital Ener

Page 99 - Kill Config option using SWM

11–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN REGISTRATION OVER GARP CHAPTER 11: VLAN REGISTRATION OVER GARPNoteThere must be on

Page 100

CHAPTER 11: VLAN REGISTRATION OVER GARP VLAN REGISTRATION OVER GARPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 11–311. Port 2 receives

Page 101 - Name Areas affected

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–11ML1200# show setupVersion: ML1200 build 2.1.0 Nov 1

Page 102

11–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN REGISTRATION OVER GARP CHAPTER 11: VLAN REGISTRATION OVER GARP• Send VLAN advertis

Page 103 - 5.5 IPv6

CHAPTER 11: VLAN REGISTRATION OVER GARP VLAN REGISTRATION OVER GARPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 11–5The unknown VLAN par

Page 104 - 5.5.3 IPv6 Addressing

11–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN REGISTRATION OVER GARP CHAPTER 11: VLAN REGISTRATION OVER GARPThe time-to-live for

Page 105 - 5.5.4 Configuring IPv6

CHAPTER 11: VLAN REGISTRATION OVER GARP VLAN REGISTRATION OVER GARPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 11–711.2 Configuring GVR

Page 106

11–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN REGISTRATION OVER GARP CHAPTER 11: VLAN REGISTRATION OVER GARPExample 11-2: Config

Page 107 - Multilink ML1200

CHAPTER 11: VLAN REGISTRATION OVER GARP VLAN REGISTRATION OVER GARPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 11–911.3 Configuring GVR

Page 108 - 6.1.3 Port Security Feature

11–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALVLAN REGISTRATION OVER GARP CHAPTER 11: VLAN REGISTRATION OVER GARP

Page 109 - 6.2.1 Commands

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–1Multilink ML1200Managed Field SwitchChapter 12: Spanning Tree Protocol (STP)Digital Ene

Page 110 - 6.2.2 Allowing MAC Addresses

12–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)While allowing onl

Page 111

CHAPTER 12: SPANNING TREE PROTOCOL (STP) SPANNING TREE PROTOCOL (STP)MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–312.2 Configuring S

Page 112

These instructions do not purport to cover all details or variations in equipment nor provide for everypossible contingency to be met in connection wi

Page 113

1–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1.4.8 User ManagementA maximum of five users can be

Page 114 - 6.2.3 Security Logs

12–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)forwarding state.

Page 115

CHAPTER 12: SPANNING TREE PROTOCOL (STP) SPANNING TREE PROTOCOL (STP)MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–5• Priority: STP us

Page 116 - 6.2.4 Authorized Managers

12–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)Example 12-3 shows

Page 117

CHAPTER 12: SPANNING TREE PROTOCOL (STP) SPANNING TREE PROTOCOL (STP)MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–7priority [port=<

Page 118 - 6.3.1 Commands

12–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)Example 12-4: Conf

Page 119

CHAPTER 12: SPANNING TREE PROTOCOL (STP) SPANNING TREE PROTOCOL (STP)MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–9Configuring STP pa

Page 120

12–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)Configuring STP p

Page 121 - 6.3.2 Logs

CHAPTER 12: SPANNING TREE PROTOCOL (STP) SPANNING TREE PROTOCOL (STP)MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 12–11Configuring STP p

Page 122 - 6.3.3 Authorized Managers

12–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSPANNING TREE PROTOCOL (STP) CHAPTER 12: SPANNING TREE PROTOCOL (STP)Configuring STP p

Page 123

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–1Multilink ML1200Managed Field SwitchChapter 13: Rapid Spanning Tree ProtocolDigital Ene

Page 124

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–131.4.9 HelpTyping the help command lists the command

Page 125

13–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOL• STP relays confi

Page 126

CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–31. Under some circ

Page 127

13–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOL13.2 Configuring R

Page 128 - 7.2.1 Commands

CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–5The variables list

Page 129

13–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOL• Bridge Max Age:

Page 130 - 7.2.2 Example

CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–7• Path Cost: This

Page 131

13–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLThe show-timers co

Page 132

CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–9Example 13-4: Conf

Page 133 - 7.3.1 Commands

13–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLConfiguring RSTP

Page 134

CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–11Configuring RSTP

Page 135

1–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION?alarmclearenableexithelplogoutpingsetshowtelnetter

Page 136

13–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLConfiguring RSTP

Page 137

CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–1313.2.2 Smart RSTP

Page 138

13–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLromode <enable

Page 139

CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–1513.3 Configuring

Page 140 - 8.1.3 TACACS+ Packet

13–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOL• Status: Indicat

Page 141 - 754717A1.CDR

CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–17Once again, if yo

Page 142 - 8.2.2 Example

13–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLThe port specific

Page 143

CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–19• P2P Ports: set

Page 144

13–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLTo configure ring

Page 145 - Z Save the settings

CHAPTER 13: RAPID SPANNING TREE PROTOCOL RAPID SPANNING TREE PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 13–21Z Once in Edit m

Page 146

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–151.5 EnerVista Secure Web Management1.5.1 Logging in

Page 147

13–22 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALRAPID SPANNING TREE PROTOCOL CHAPTER 13: RAPID SPANNING TREE PROTOCOLNoteOnly 2 ports

Page 148 - 9.2.1 Commands

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–1Multilink ML1200Managed Field SwitchChapter 14: Quality of ServiceDigital EnergyMultili

Page 149 - 9.3 Port Setup

14–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICETo make the preemptive queuing possibl

Page 150

CHAPTER 14: QUALITY OF SERVICE QUALITY OF SERVICEMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–3FIGURE 14–2: IP Precedence ToS Field i

Page 151 - 9.3.3 Back Pressure

14–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICE14.2 Configuring QoS through the Comma

Page 152

CHAPTER 14: QUALITY OF SERVICE QUALITY OF SERVICEMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–5The show qos command displays the QoS

Page 153 - 9.3.4 Broadcast Storms

14–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICE14.2.2 ExampleThe following example sh

Page 154

CHAPTER 14: QUALITY OF SERVICE QUALITY OF SERVICEMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–7Configuring QoS (continued)ML1200(qos)

Page 155 - 9.3.5 Link Loss Alert

14–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICEConfiguring QoS (continued)Port priori

Page 156

CHAPTER 14: QUALITY OF SERVICE QUALITY OF SERVICEMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–914.3 Configuring QoS with EnerVista Se

Page 157 - 9.4.1 Commands

1–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONFIGURE 1–3: Login screenFor the first time, Z Login

Page 158 - 9.4.2 Port Setup

14–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICEZ Select the Port and the type of QoS

Page 159 - In these windows:

CHAPTER 14: QUALITY OF SERVICE QUALITY OF SERVICEMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 14–11Next, a tag-based QoS is enabled on p

Page 160

14–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALQUALITY OF SERVICE CHAPTER 14: QUALITY OF SERVICEIn the following window, a ToS is ena

Page 161 - 9.4.3 Broadcast Storms

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–1Multilink ML1200Managed Field SwitchChapter 15: IGMPDigital EnergyMultilinIGMP15.1 Over

Page 162

15–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMPzero. On the other hand, a transient group is dynamically assigned

Page 163 - Chapter 10: VLAN

CHAPTER 15: IGMP IGMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–3The figure below shows a network running IGMP.FIGURE 15–1: Advanta

Page 164 - VLAN CHAPTER 10: VLAN

15–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMPEither of these switches can operate as querier because a multicas

Page 165 - 10.1.2 Tag VLAN vs. Port VLAN

CHAPTER 15: IGMP IGMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–515.1.4 Reserved Addresses Excluded from IP Multicast (IGMP) Filter

Page 166

15–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMP15.2 Configuring IGMP through the Command Line Interface15.2.1 Com

Page 167 - 10.2.2 Commands

CHAPTER 15: IGMP IGMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–7show-groupThe following command sequence illustrates how to displa

Page 168

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–17FIGURE 1–4: Welcome screen1.5.2 Privilege Levels• O

Page 169 - 10.3.1 Description

15–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMP15.2.2 ExampleThe following example shows how to configure IGMP.Ex

Page 170

CHAPTER 15: IGMP IGMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–9Configuring IGMP (continued)ML1200(igmp)## set-leave enableIGMP im

Page 171

15–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMPConfiguring IGMP (continued)ML1200(igmp)## show igmpIGMP State :

Page 172

CHAPTER 15: IGMP IGMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 15–1115.3 Configuring IGMP with EnerVista Secure Web Management softwa

Page 173

15–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIGMP CHAPTER 15: IGMPZ Click on the Edit button to edit the IGMP parameters. This scre

Page 174 - 10.4.2 Commands

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–1Multilink ML1200Managed Field SwitchChapter 16: SNMPDigital EnergyMultilinSNMP16.1 Over

Page 175 - 10.4.3 Example

16–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPauthoritative. When an SNMP message does not expect a response, th

Page 176 - VLAN type to be Tag VLAN

CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–3• SNMP user - A person for which an SNMP management operation is p

Page 177

16–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMP• RFC 1907, Management Information Base for Version 2 of the Simpl

Page 178 - (continued on next page)

CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–516.2 Configuring SNMP through the Command Line Interface16.2.1 Com

Page 179

1–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONIn the following example below, the user peter was

Page 180

16–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPtrap <add|delete> id=<id> [type=<v1|v2|inform>]

Page 181 - 10.5.1 Description

CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–7Example 16-1: Configuring SNMPML1200# set snmp type=v1SNMP version

Page 182

16–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPConfiguring SNMP (continued)ML1200(snmpv3)## trap add id=1 type=v1

Page 183

CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–9Configuring SNMP (continued)ML1200(snmpv3)## show-groupID Group Na

Page 184

16–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPConfiguring SNMP (continued)ML1200(snmpv3)## show-accessID View N

Page 185

CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–1116.3 Configuring SNMP with EnerVista Secure Web Management softwa

Page 186

16–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPThe following window illustrates changes to the SNMP community pa

Page 187

CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–13Z When done adding stations, click OK.Z When adding SNMP trap rec

Page 188 - FIGURE 11–1: GVRP operation

16–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPNote the different types of trap receivers added.Stations can be

Page 189 - 754722A1.CDR

CHAPTER 16: SNMP SNMPMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 16–1516.4 Configuring RMON16.4.1 DescriptionThe switch supports RMON (

Page 190

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–19After successfully adding a user, the added user is

Page 191

16–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALSNMP CHAPTER 16: SNMPML1200(rmon)## show rmon eventRMON Event Default Owner : testRMON

Page 192

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–1Multilink ML1200Managed Field SwitchChapter 17: Miscellaneous Digital EnergyMultilinMis

Page 193 - 11.2.2 GVRP Operation Notes

17–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDS• SMTP alerts can be enabled o

Page 194

CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–3The delete command deletes the

Page 195 - 11.3.1 Example

17–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDSExample 17-1: Configuring SMTP

Page 196

CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–517.2 Statistics17.2.1 Viewing

Page 197 - Protocol (STP)

17–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDSThe following figure displays

Page 198

CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–717.3 Serial Connectivity17.3.1

Page 199 - 12.2 Configuring STP

17–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDS17.4 History17.4.1 CommandsThe

Page 200

CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–917.5 Ping17.5.1 Ping through t

Page 201

1–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONThe firmware will prompt to verify the delete comma

Page 202

17–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDS17.6 Prompt17.6.1 Changing th

Page 203

CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–1117.7 System Events17.7.1 Desc

Page 204

17–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDSEvent logs can be exported to

Page 205

CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–13For viewing each specific log

Page 206

17–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDS17.8 Command Reference17.8.1

Page 207

CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–15• show smtp: displays e-mail

Page 208

17–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDS• save •whoami: display the u

Page 209 - Protocol

CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–17• portaccess •reauth •setport

Page 210

17–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDSThe port mirroring commands a

Page 211

CHAPTER 17: MISCELLANEOUS COMMANDS MISCELLANEOUS COMMANDSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 17–19The Simple Mail Transfer Prot

Page 212 - 13.2.1 Normal RSTP

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–21After clicking on the edit icon, the screen opens u

Page 213

17–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMISCELLANEOUS COMMANDS CHAPTER 17: MISCELLANEOUS COMMANDSThe VLAN commands are shown b

Page 214

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–1Multilink ML1200Managed Field SwitchChapter 18: Modbus ProtocolDigital EnergyMultilinMo

Page 215

18–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOLThe commands enable the Modbus protocol and

Page 216

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–318.1.3 EnerVista SettingsTo modify the Modbu

Page 217

18–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL18.2 Memory Mapping18.2.1 Modbus Memory MapT

Page 218 - Configuring RSTP (continued)

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–50062 Port 13 type 0 to 6 1 F4 Varies0063 Por

Page 219

18–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0090 Port 27 link status 0 to 1 1 F3 00091 P

Page 220

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–700BE Port 9 activity 0 to 1 1 F3 000BF Port

Page 221

18–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL00F0 Port 1: Number of late collisions occur

Page 222

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–90128 Port 2: Number of 128 to 255 byte frame

Page 223 - 13.3.1 Normal RSTP

TOC TABLE OF CONTENTSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL TOC–ITable of Contents1: INTRODUCTION GETTING STARTED ...

Page 224

1–22 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1.5.5 HelpHelp for the EnerVista Secure Web Managem

Page 225

18–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0160 Port 3: Number of 1023 to maximum byte

Page 226

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–110198 Port 4: Number of multicast frames sen

Page 227

18–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL01D0 Port 6: Number of bytes received 0 to

Page 228

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–130208 Port 7: Number of frames sent 0 to 429

Page 229

18–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0240 Port 8: Number of broadcast frames rec

Page 230

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–150278 Port 9: Number of oversized frames rec

Page 231

18–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL02B0 Port 10: Number of collisions occurred

Page 232 - 14.1.4 IP Precedence

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–1702E8 Port 11: Number of 65 to 127 byte fram

Page 233 - IP precedence

18–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0320 Port 12: Number of 512 to 1023 byte fr

Page 234 - 14.2.1 Commands

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–190358 Port 13: Number of dropped received pa

Page 235

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–23Z Confirm the logout by selecting OK in the pop-up

Page 236 - 14.2.2 Example

18–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0390 Port 14: Number of <64 byte fragmen

Page 237 - Configuring QoS (continued)

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–2103C8 Port 16: Number of frames received 0 t

Page 238

18–22 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0400 Port 17: Total frames received 0 to 42

Page 239 - 14.3.1 Description

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–230438 Port 18: Number of frames with CRC err

Page 240

18–24 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0470 Port 19: Number of jabber frames recei

Page 241

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–2504A8 Port 20: Number of 64-byte frames rece

Page 242

18–26 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL04E0 Port 21: Number of 256 to 511 byte fra

Page 243 - Chapter 15: IGMP

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–270518 Port 22: Number of MAC error packets 0

Page 244 - IGMP CHAPTER 15: IGMP

18–28 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0550 Port 23: Number of broadcast frames se

Page 245 - CHAPTER 15: IGMP IGMP

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–290588 Port 25: Number of bytes sent 0 to 429

Page 246 - 15.1.3 IP Multicast Filters

1–24 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION1.6 ML1200 Firmware Updates1.6.1 Updating Multilink

Page 247 - 15.1.5 IGMP Support

18–30 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL05C0 Port 26: Total bytes received 0 to 429

Page 248 - 15.2.1 Commands

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–3105F8 Port 27: Number of multicast frames re

Page 249

18–32 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0630 Port 28: Number of bad fragments recei

Page 250 - 15.2.2 Example

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–330668 Port 29: Number of late collisions occ

Page 251

18–34 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL06A0 Port 30: Number of 128 to 255 byte fra

Page 252

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–3506D8 Port 31: Number of 1023 to maximum byt

Page 253 - 15.3.1 Example

18–36 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL0710 Port 32: Number of multicast frames se

Page 254

CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOLMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–3718.2.2 Format Codes• Bitmap: 32-bit group o

Page 255 - Chapter 16: SNMP

18–38 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALMODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL

Page 256 - SNMP CHAPTER 16: SNMP

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL A–1Multilink ML1200Managed Field SwitchAppendix ADigital EnergyMultilinAppendix AA.1 Revisi

Page 257 - 16.1.4 Standards

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–25Z Save the existing configuration (refer to section

Page 258

A–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALAPPENDIX A CHAPTER A: APPENDIX AA.2 WarrantyA.2.1 GE Multilin Warranty StatementGeneral

Page 259 - 16.2.1 Commands

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL B–1Multilink ML1200Managed Field SwitchAppendix B: DC Power InputDigital EnergyMultilinDC P

Page 260 - 16.2.2 Example

B–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALDC POWER INPUT CHAPTER B: DC POWER INPUTB.1 Specifications for Multilink ML1200 Switches

Page 261

CHAPTER B: DC POWER INPUT DC POWER INPUTMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL B–3B.2 -48 V DC, 24 V DC and 125 V DC Power, Theory

Page 262

B–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALDC POWER INPUT CHAPTER B: DC POWER INPUTB.3 Applications for DC Powered Ethernet Switche

Page 263

CHAPTER B: DC POWER INPUT DC POWER INPUTMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL B–5B.4 ML1200, -48 V, 24 V, 125 V DC InstallationTh

Page 264

B–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALDC POWER INPUT CHAPTER B: DC POWER INPUTB.5 UL Requirements for DC-powered units48VDC pr

Page 265 - 16.3.1 Example

CHAPTER B: DC POWER INPUT DC POWER INPUTMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL B–7B.6 OperationOperation of Multilink ML1200 Switc

Page 266

B–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALDC POWER INPUT CHAPTER B: DC POWER INPUT

Page 267

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL C–1Multilink ML1200Managed Field SwitchAppendix C: Internal DC Dual-Source Power Input Digi

Page 268

1–26 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTIONZ Once the file transfer is completed reboot the sw

Page 269 - 16.4 Configuring RMON

C–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTERNAL DC DUAL-SOURCE POWER INPUT OPTION CHAPTER C: INTERNAL DC DUAL-SOURCE POWER INPU

Page 270 - ML1200(rmon)## exit

CHAPTER C: INTERNAL DC DUAL-SOURCE POWER INPUT OPTION INTERNAL DC DUAL-SOURCE POWER INPUT OPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MA

Page 271 - Chapter 17: Miscellaneous

C–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTERNAL DC DUAL-SOURCE POWER INPUT OPTION CHAPTER C: INTERNAL DC DUAL-SOURCE POWER INPU

Page 272 - 17.1.2 Commands

CHAPTER C: INTERNAL DC DUAL-SOURCE POWER INPUT OPTION INTERNAL DC DUAL-SOURCE POWER INPUT OPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MA

Page 273 - 17.1.3 Example

C–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTERNAL DC DUAL-SOURCE POWER INPUT OPTION CHAPTER C: INTERNAL DC DUAL-SOURCE POWER INPU

Page 274

CHAPTER 1: INTRODUCTION INTRODUCTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–27Z Reboot the switch when the transfer is complete.

Page 275 - 17.2 Statistics

1–28 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINTRODUCTION CHAPTER 1: INTRODUCTION

Page 276

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–1Multilink ML1200Managed Field SwitchChapter 2: Product DescriptionDigital EnergyMultilin

Page 277 - 17.3.1 Description

2–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTIONpoints, IP phones) that comply with th

Page 278 - 17.4 History

CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–32.1.1 Four-port SFF fiber modules (CC

Page 279 - 17.5 Ping

TOC–II MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALTABLE OF CONTENTSALARM CONTACTS FOR MONITORING INTERNAL POWER, AND SOFTWARE TRAPS .

Page 280 - 17.6 Prompt

2–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTION2.1.2 Four-Port Copper Module, C1 Modu

Page 281 - 17.7 System Events

CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–5The LEDs on C2 PoE modules are slightl

Page 282 - 17.7.3 EnerVista Example

2–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTION2.1.6 SFP Gigabit (1000Mbps) port modu

Page 283

CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–72.1.8 Frame Buffering and Flow Control

Page 284 - 17.8 Command Reference

2–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTION2.2 Features and Benefits• Managed swi

Page 285

CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–9QoS, Port- and tag-based VLANs, GVRP,

Page 286 - 17.8.2 Configuration commands

2–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTION2.3 ApplicationsMultilink ML1200 Fiel

Page 287

CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 2–11Extended temperature ratings and a va

Page 288

2–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALPRODUCT DESCRIPTION CHAPTER 2: PRODUCT DESCRIPTIONThe ML1200 Managed Fiber with the Rin

Page 289

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 3–1Multilink ML1200Managed Field SwitchChapter 3: InstallationDigital EnergyMultilinInstal

Page 290

TOC TABLE OF CONTENTSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL TOC–IIISECURITY LOGS ...

Page 291 - Chapter 18: Modbus Protocol

3–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINSTALLATION CHAPTER 3: INSTALLATION3.2 Connecting Ethernet MediaThe Multilink ML1200 Sw

Page 292 - For example

CHAPTER 3: INSTALLATION INSTALLATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 3–33.2.0.2 Connecting Fiber Optic SC-type, "Snap-I

Page 293 - 18.1.3 EnerVista Settings

3–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINSTALLATION CHAPTER 3: INSTALLATION3.2.0.5 Connecting Twisted Pair (CAT5e or better, Un

Page 294 - 18.2 Memory Mapping

CHAPTER 3: INSTALLATION INSTALLATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 3–53.2.0.7 Connecting Fiber Optic Cable to SFP Transcei

Page 295

3–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINSTALLATION CHAPTER 3: INSTALLATION3.3 Mechanical Installation3.3.1 DIN-Rail Mounting t

Page 296

CHAPTER 3: INSTALLATION INSTALLATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 3–7For best cooling of the ML1200, attach the metal bra

Page 297

3–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINSTALLATION CHAPTER 3: INSTALLATION3.4 Electrical Installation3.4.1 Powering the Multil

Page 298

CHAPTER 3: INSTALLATION INSTALLATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 3–9The Alarm Contacts are on the front left area (next

Page 299

3–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALINSTALLATION CHAPTER 3: INSTALLATION3.4.4 Connecting a Management Console Terminal to M

Page 300

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–1Multilink ML1200Managed Field SwitchChapter 4: OperationDigital EnergyMultilinOper ation

Page 301

TOC–IV MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALTABLE OF CONTENTSWEB MANAGEMENT SOFTWARE ...

Page 302

4–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION4.1.1.2 Address LearningAll Multilink ML1200 units have ad

Page 303

CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–3The auto-negotiation logic will attempt to operate in desc

Page 304

4–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION4.1.5 Power Budget Calculations for ML1200 PM’s with Fiber

Page 305

CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–5Note* The use of either multi-mode or single-mode fiber to

Page 306

4–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION4.2 Multilink ML1200 Managed Field Switch Port ModulesThis

Page 307

CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–7Multilink ML1200 Managed Switch, the copper port supports

Page 308

4–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION4.2.2.4 CB Module, 2 Ports @100Mbps single-mode FX-SC-type

Page 309

CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–9Each port has an Activity (ACT) LED indicating packets bei

Page 310

4–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATIONThe cable end is a “plug-in” connector with both fiber st

Page 311

CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–11Each port has an Activity (ACT) LED indicating packets be

Page 312

TOC TABLE OF CONTENTSMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL TOC–VDESCRIPTION ...

Page 313

4–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION• In the case where the 48VDC power in not internally con

Page 314

CHAPTER 4: OPERATION OPERATIONMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 4–13described in this section or if the Multilink ML1200 Swit

Page 315

4–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALOPERATION CHAPTER 4: OPERATION

Page 316

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–1Multilink ML1200Managed Field SwitchChapter 5: IP AddressingDigital EnergyMultilinIP Add

Page 317

5–2 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGZ Edit the IP address information.Besides manually

Page 318

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–35.2 Importance of an IP Address5.2.1 DHCP and boot

Page 319

5–4 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGThe bootimg argument is only valid with the bootp

Page 320

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–5Z After the changes are completed for each section

Page 321

5–6 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGThe show console command can show the status of th

Page 322

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–7For example:ML1200# userML1200(user)## useraccess

Page 323

TOC–VI MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALTABLE OF CONTENTSMAIN COMMANDS ...

Page 324

5–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSING5.3 Setting Parameters5.3.1 Setting Serial Port Pa

Page 325

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–9ML1200# show sysconfigSystem Name: ML1200System Co

Page 326

5–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGTo set the time to be 08:10 am in the -5 hours fr

Page 327 - 18.2.2 Format Codes

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–11To set the SNTP server to be 3.94.210.5 (with a t

Page 328

5–12 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGAfter the proper SNTP values are entered, click O

Page 329 - Appendix A

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–13The Time Out value is in seconds. Note the time s

Page 330 - A.2 Warranty

5–14 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSING5.4 System Configuration5.4.1 Saving and Loading

Page 331 - Appendix B: DC Power Input

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–15Using Config Download, examination of the content

Page 332

5–16 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGFIGURE 5–1: Contents of a config fileNote1. A con

Page 333

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–175.4.3 Displaying configurationUsing SWM, the need

Page 334

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 1–1Multilink ML1200Managed Field SwitchChapter 1: IntroductionDigital EnergyMultilinIntrodu

Page 335

5–18 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGFIGURE 5–2: ’show config’ command output# System

Page 336

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–19FIGURE 5–3: Displaying specific modules using the

Page 337 - B.6 Operation

5–20 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGFIGURE 5–4: Displaying configuration for differen

Page 338

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–21Additional capabilities have been added to save a

Page 339 - Source Power Input

5–22 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSING5.4.5 Script FileScript file is a file containing

Page 340

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–23In the above example, note that all the commands

Page 341

5–24 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGThis process can also be used to update new softw

Page 342

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–25Z If the changes need to be ignored, click on Can

Page 343

5–26 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUALIP ADDRESSING CHAPTER 5: IP ADDRESSINGZ To add a host, click the Add button.Z Fill in a

Page 344 - C.5 Installation

CHAPTER 5: IP ADDRESSING IP ADDRESSINGMULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 5–27Z To delete or edit the entries, use the delete o

Comments to this Manuals

No comments